Schneider Electric C10F4TM032 — Molded Case Circuit Breakers (MCCB)

Schneider Electric C10F4TM032 ComPacT NSX100F, 32 A, 4P, 85

MPNC10F4TM032
Active

Schneider Electric ComPacT NSX, NSX100F, thermal-magnetic circuit breaker, 32 A, 4P, 85 kA Icu at 240 V AC, Type F breaking capacity.

$425.57 – $547.78Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C10F4TM032 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
C10F4TM032 — Electrical
ParameterValue
[In] rated current32 A at 40 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 25 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
[Ics] rated service breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz
C10F4TM032 — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameNSX100F
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C10F4TM032 is a ComPacT NSX100F circuit breaker with a 32 A thermal-magnetic TM-D trip unit, 4 poles, and an F breaking capacity code — meaning 36 kA Icu at 380/415 V AC. It's rated 85 kA Icu at 220/240 V AC and still delivers 22 kA Icu at 525 V AC, so it covers both light commercial and heavy industrial distribution panels without swapping frames. The TM-D trip unit gives you L (thermal overload) and I (magnetic short-circuit) protection, with the neutral protection set at 1 x Ir for a 4D configuration. That means the breaker tracks overload on all four poles equally — no derating guesswork when you land a balanced 3-phase plus neutral feed. Mechanical durability is rated at 50,000 cycles, with electrical durability ranging from 50,000 cycles at 440 V In/2 down to 10,000 cycles at 690 V In. For a panel that sees regular switching — like a pump start/stop or a conveyor section — that's a solid service life before you're pulling a replacement.

The 140 mm width and 161 mm height give it a footprint that matches standard ComPacT NSX panel cutouts, and the 35 mm connection pitch lines up with common busbar systems and terminal blocks. Front connections on both the line and load sides mean you can bus it in a panel without flipping the breaker or adding awkward right-angle adapters. The toggle control is right there on the front — no pushbutton or rotary handle to confuse a maintenance crew pulling a lockout.

Environmental and compliance specs that matter for the install

IP40 enclosure protection keeps dust and fingers out, and the IK07 impact rating means it'll survive a tool bump in a crowded panel. Operating altitude goes to 2000 m without derating, and up to 5000 m with derating — worth checking if your site sits above a mile high. Compliant with EN/IEC 60947-2 and suitable for isolation per that standard, so it doubles as a visible-break disconnect when the toggle is in the OFF position. No separate isolator needed on the load side for most code jurisdictions.

Frequently asked questions

What is C10F4TM032's breaking capacity at 415 V?

At 380/415 V AC, the C10F4TM032 delivers 36 kA Icu per IEC 60947-2, which is the F breaking capacity code rating.

What compliance standards does C10F4TM032 meet?

The C10F4TM032 is compliant with EN/IEC 60947-2 and is suitable for isolation per that standard. It carries IP40 and IK07 ratings, pollution degree 3, and overvoltage category III.

MPN
C10F4TM032