Schneider Electric C10F4TM100C — Molded Case Circuit Breakers (MCCB)

Schneider Electric C10F4TM100C ComPacT NSX100F MCCB, 100 A,

MPNC10F4TM100C
Active

Schneider Electric ComPacT NSX100F, 4-pole MCCB, 100 A TM-D thermal-magnetic trip, 36 kA Icu at 415 V AC, toggle control, backplate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C10F4TM100C — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
C10F4TM100C — Electrical
ParameterValue
[In] rated current100 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz
C10F4TM100C — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameNSX100F
StandardsEN/IEC 60947-2

Product details

The TM-D provides L (thermal overload) and I (magnetic short-circuit) protection. At 415 V AC the breaker delivers 36 kA Icu (breaking capacity code F). The breaker is listed as current production (lifecycle stage: current). It remains a standard catalogue item through Schneider distribution channels.

The 4-pole body is 140 mm wide × 161 mm high × 86 mm deep — a compact footprint for a 100 A frame. Front-front connections (upside and downside both front-facing) simplify busbar or cable routing in a distribution panel. The toggle handle gives local manual switching; no motor operator is built in, but the NSX range accepts plug-in auxiliaries and shunt trips (5 accessory slots available).

Electrical durability and isolation

Rated for 50,000 mechanical cycles and 30,000 electrical cycles at rated current (440 V In). That is a solid service life for a panel main or feeder breaker — expect to replace it on a planned maintenance schedule, not because it wears out prematurely. The breaker is certified for isolation per EN/IEC 60947-2, meaning it provides a visible-break isolation function when open (no separate disconnect switch needed downstream for the branch circuit it feeds).

Frequently asked questions

What does the TM-D trip unit protect against?

L (thermal overload) protects against sustained overcurrents that heat conductors; I (magnetic short-circuit) trips instantly on high fault currents. The thermal element is rated 100 A at 50 °C.

MPN
C10F4TM100C