Schneider Electric C10F6TM016C — Molded Case Circuit Breakers (MCCB)

C10F6TM016C ComPacT NSX100F 16A 4P Circuit Breaker, 36 kA 41

MPNC10F6TM016C
Active

Schneider Electric ComPacT NSX NSX100F, 16 A, 4P, thermal-magnetic TM-D trip unit, 36 kA Icu at 415 V AC, IP40, toggle control.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C10F6TM016C — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
C10F6TM016C — Electrical
ParameterValue
[In] rated current16 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz
C10F6TM016C — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameNSX100F
StandardsEN/IEC 60947-2

Product details

The TM-D trip gives you fixed thermal overload (L) and fixed magnetic short-circuit (I) protection; no adjustment dials, so what you order is what protects the circuit. The 4-pole configuration (3 phases + neutral) suits a 3-phase 4-wire system where the neutral is switched. Mounts on a backplate, not a DIN rail — this is a bolted-down MCCB for a panel or enclosure, with front connections top and bottom. The 140 mm width, 161 mm height, and 86 mm depth fit the standard NSX100F cutout. The IK07 impact rating means it withstands a 2 J hammer blow — robust enough for an industrial panel door.

Compliance and approvals

Suitability for isolation is confirmed per that standard — you can use it as a disconnecting means. No earth-leakage protection built in — the TM-D trip handles overload and short-circuit only. If you need ground-fault protection, you add a Vigi module externally. The breaker is rated for horizontal and vertical mounting, flat on the backplate, which gives flexibility in panel layout.

Frequently asked questions

What is the breaking capacity of C10F6TM016C at 415 V?

36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. That is the F breaking capacity code — the standard rating for this frame size at 415 V.

What does the TM-D trip unit protect against?

Thermal overload (L) and fixed magnetic short-circuit (I). No adjustment — the thermal element is sized for 16 A at 50 °C, and the magnetic pickup is fixed at a factory-set multiple of In.