Skip to main content
Schneider Electric C10F6TM032C — Miniature Circuit Breakers (MCB)

C10F6TM032C ComPacT NSX100F 32A Thermal-Magnetic MCCB, 36kA

MPNC10F6TM032C
Active

Schneider Electric ComPacT NSX100F, 4-pole thermal-magnetic MCCB, 32 A rated current, 36 kA Icu at 415 V AC, toggle control, IP40.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

C10F6TM032C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution

Ratings

C10F6TM032C — Ratings
ParameterValue
Rated current (In)32 A at 50 °C
Poles configuration4P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII

Protection

C10F6TM032C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles

Mechanical

C10F6TM032C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle

Environmental

C10F6TM032C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %

Approvals

C10F6TM032C — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Specifications

C10F6TM032C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

It is a 4-pole device (4P) with toggle control, designed for distribution applications per EN/IEC 60947-2. The breaking capacity is 85 kA Icu at 220/240 V AC and 36 kA Icu at 380/415 V AC (50/60 Hz), which defines the F breaking capacity code. At 440 V it drops to 35 kA, at 500 V to 25 kA, at 525 V to 22 kA, and at 660/690 V to 8 kA. For a 415 V panel, the 36 kA rating is the figure that governs fault-current coordination upstream. The thermal-magnetic trip unit provides L (overload protection, thermal) and I (short-circuit protection, magnetic) functions. Neutral protection is set to no protection (3D).

The breaker carries IP40 protection (finger-safe, no water ingress) and IK07 impact resistance.

Connection pitch is 35 mm. The 4-pole unit occupies a 140 mm-wide footprint on the backplate. Electrical endurance is 50,000 cycles at 440 V In/2, 30,000 cycles at 440 V In, and 10,000 cycles at 690 V In; mechanical endurance is 50,000 cycles. Operating altitude is 0–2000 m without derating, 2000–5000 m with derating. Relative humidity range is 0–95 %. Overvoltage category III.

Frequently asked questions

Where can I buy C10F6TM032C?

The C10F6TM032C is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of C10F6TM032C at 415 V?

At 380/415 V AC 50/60 Hz, the breaking capacity is 36 kA Icu per IEC 60947-2. This is the F breaking capacity code.

What compliance documentation does Schneider Electric provide for C10F6TM032C?

The breaker is certified to EN/IEC 60947-2 and carries IP40 and IK07 ratings. Specific RoHS, REACH, or UL documentation should be verified against the manufacturer's current declarations for this order code.

MPN