Skip to main content
Schneider Electric C10F6TM040C — Miniature Circuit Breakers (MCB)

Schneider Electric C10F6TM040C ComPacT NSX 40A MCCB, 36kA 41

MPNC10F6TM040C
Active

Schneider Electric ComPacT NSX, NSX100F, circuit breaker, 40 A, 4P, TM-D trip unit, 36 kA Icu at 415 V AC, toggle control.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

C10F6TM040C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution

Ratings

C10F6TM040C — Ratings
ParameterValue
Rated current (In)40 A at 50 °C
Poles configuration4P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII

Protection

C10F6TM040C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles

Mechanical

C10F6TM040C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle

Environmental

C10F6TM040C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %

Approvals

C10F6TM040C — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Specifications

C10F6TM040C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C10F6TM040C is a Schneider Electric ComPacT NSX100F moulded-case circuit breaker with a 40 A thermal-magnetic TM-D trip unit, four poles, and a 36 kA interrupting capacity at 415 V AC. The 40 A rating at 50 °C covers typical lighting, small motor, or general distribution loads without derating in a warm enclosure.

At 220/240 V it jumps to 85 kA Icu, and at 690 V it still holds 8 kA Icu. That spread means the same breaker can be used across different voltage levels in the same plant without swapping frames. The utilisation category A (non-selectivity-oriented) means it's designed to clear faults fast rather than coordinate with downstream devices — fine for a main or branch breaker where you want quick trip, not for a selective main where you need time delay.

Mounts flat on a backplate — no DIN rail here. The 140 mm width and 161 mm height fit standard MCCB cutouts in distribution boards. IP40 front face keeps out tools and fingers; IK07 impact rating means it survives a 2 J hammer blow — fine for a locked electrical room but not for a washdown area.

Durability and duty cycles

Rated for 50,000 mechanical operations and 30,000 electrical cycles at rated current (40 A, 440 V). That's a solid 10+ years of daily switching in a machine-tool or conveyor application. At half rated current (20 A) the electrical endurance doubles to 50,000 cycles — typical for lightly loaded feeder breakers that cycle with the shift schedule.

Frequently asked questions

Where can I buy C10F6TM040C and get a price?

This part is sourced to order against an RFQ through independent industrial distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the breaking capacity of C10F6TM040C at 415 V?

36 kA Icu at 380/415 V AC, 50/60 Hz, per IEC 60947-2. At 440 V it's 35 kA; at 500 V it's 25 kA.

What compliance documentation does this breaker carry?

It meets EN/IEC 60947-2, is suitable for isolation per that standard, and carries IP40 and IK07 ratings. Pollution degree 3 per IEC 60664-1. No earth-leakage protection built in.

MPN