Skip to main content
Schneider Electric C10F6TM050C — Molded Case Circuit Breakers (MCCB)

C10F6TM050C ComPacT NSX 50A MCCB, 36kA 415V AC, TM-D Trip

MPNC10F6TM050C
Active

Schneider Electric ComPacT NSX, NSX100F, 4P, 50 A thermal-magnetic TM-D trip, 36 kA Icu at 415 V AC, toggle control, backplate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C10F6TM050C — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
C10F6TM050C — Electrical
ParameterValue
[In] rated current50 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz
C10F6TM050C — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameNSX100F
StandardsEN/IEC 60947-2

Product details

It is a 4-pole device rated for distribution applications, with a breaking capacity of 36 kA Icu at 415 V AC (50/60 Hz) per IEC 60947-2. The F breaking-capacity code means it delivers 36 kA at 415 V — the most common industrial low-voltage fault level — so it handles the majority of panelboard and sub-distribution duties without needing a higher-rated frame.

At 440 V AC the Icu is 35 kA, at 500 V it drops to 25 kA, and at 690 V it is 8 kA — so the voltage class of your system determines whether this breaker clears a fault without damage. Electrical durability is 50,000 cycles at 440 V at half rated current (In/2), 30,000 cycles at full In, and 10,000 cycles at 690 V full In. Mechanical durability is 50,000 cycles. For a distribution breaker in a panel that sees infrequent switching (a main or feeder), this is ample; for a machine-tool disconnect cycled multiple times per shift, the electrical endurance at full load is the number to watch. The IP40 enclosure rating keeps out tools and wires >1 mm; the IK07 impact rating means it withstands a 2 J hammer blow to the front face.

Neutral is on the left; the neutral protection setting is 3D (no protection) — if you need a fully protected neutral, this is not the variant.

Frequently asked questions

What is the breaking capacity of C10F6TM050C at 415 V?

36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. This is the F breaking-capacity code rating, which covers the most common industrial fault level.

What does the TM-D trip unit protect against?

L (thermal overload) and I (magnetic short-circuit) protection. The thermal element handles sustained overcurrents; the magnetic element trips instantaneously on high fault currents.

Where can I buy C10F6TM050C?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does C10F6TM050C comply with?

It is designed and tested to EN/IEC 60947-2 for low-voltage switchgear and controlgear. It is also suitable for isolation per that standard.

MPN
C10F6TM050C