Schneider Electric C10F6TM063C — Molded Case Circuit Breakers (MCCB)

C10F6TM063C ComPacT NSX100F 63A 4P MCCB, 36kA 415V

MPNC10F6TM063C
Active

Schneider Electric ComPacT NSX100F, 63 A, 4-pole, thermal-magnetic TM-D trip unit, 36 kA Icu at 415 V AC, toggle control, IP40.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C10F6TM063C — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
C10F6TM063C — Electrical
ParameterValue
[In] rated current63 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz
C10F6TM063C — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameNSX100F
StandardsEN/IEC 60947-2

Product details

The C10F6TM063C is a Schneider Electric ComPacT NSX100F moulded-case circuit breaker with a 63 A thermal-magnetic TM-D trip unit, 4 poles, and a breaking capacity code of F — 36 kA Icu at 415 V AC. The TM-D trip gives you L (thermal) overload protection and I (magnetic) short-circuit protection in one block — no electronic adjustments, no auxiliary power needed. At 63 A and 50 °C ambient, it's sized for a feeder or a large submain in a 400 V class installation.

Breaking capacity — what the F code means in practice

At higher voltages the rating drops — 25 kA at 500 V, 22 kA at 525 V, 8 kA at 690 V — so if your line side is a 690 V transformer secondary, this frame still works but coordination gets tighter.

The 4-pole body is 140 mm wide, 161 mm tall, 86 mm deep, with a 35 mm connection pitch that matches standard busbar systems.

Endurance and duty cycle

Mechanical durability is 50,000 cycles; electrical durability varies with load — 30,000 cycles at rated current 440 V, 10,000 cycles at 690 V. That's enough for a main breaker that sees infrequent switching, but if you're cycling it weekly as a disconnect, the 50,000-cycle mechanical life gives decades of service.

Frequently asked questions

What is C10F6TM063C's breaking capacity at 415 V?

36 kA Icu at 380/415 V AC, 50/60 Hz, per IEC 60947-2. That's the F breaking capacity code on the NSX100F frame.

MPN
C10F6TM063C