The TM-D trip combines a thermal bimetal for overload protection (L) and a magnetic coil for short-circuit protection (I), both adjustable on the trip unit. At 220/240 V it handles 85 kA; at 690 V it drops to 8 kA — the voltage derating is steep, so verify the available fault current at your system voltage. The breaker is 4-pole (4P) with the neutral on the left, configured for 3D neutral protection (no protection on the neutral pole). Mounting is backplate, horizontal or vertical, with front connections top and bottom.
Schneider Electric C10F6TM100C ComPacT NSX100F MCCB, 100 A,
Schneider Electric ComPacT NSX, NSX100F, circuit breaker, 100 A at 50 °C, TM-D trip unit, 4P, 36 kA Icu at 415 V AC, IP40.
Specifications
Identification
| Parameter | Value |
|---|---|
| Product name | ComPacT NSX |
| Product range | ComPacT |
| Product/component type | Circuit breaker |
| Device application | Distribution |
Ratings
| Parameter | Value |
|---|---|
| Rated current (In) | 100 A at 50 °C |
| Poles configuration | 4P |
| Breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated service breaking capacity (Ics) | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated operational voltage (Ue) | 690 V AC 50/60 Hz |
| Rated insulation voltage (Ui) | 800 V AC 50/60 Hz |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Network type (AC/DC) | AC |
| Network frequency | 50/60 Hz |
| Utilisation category | Category A |
| Overvoltage category | III |
Protection
| Parameter | Value |
|---|---|
| Trip unit technology | Thermal-magnetic |
| Earth-leakage protection | Without |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Electrical durability (cycles) | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Mechanical durability (cycles) | 50000 cycles |
Mechanical
| Parameter | Value |
|---|---|
| Mounting support | Backplate |
| Control type | Toggle |
Environmental
| Parameter | Value |
|---|---|
| Operating ambient temperature | -25...70 °C |
| Storage ambient temperature | -50...85 °C |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Relative humidity | 0...95 % |
Approvals
| Parameter | Value |
|---|---|
| Standards | EN/IEC 60947-2 |
Specifications
| Parameter | Value |
|---|---|
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Trip unit protection functions | LI |
Product details
Frequently asked questions
What is the breaking capacity of C10F6TM100C at 415 V?
The breaking capacity is 36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, which corresponds to the F breaking capacity code.
Where can I buy C10F6TM100C?
This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.
What compliance documentation does Schneider Electric provide for C10F6TM100C?
The breaker is certified to EN/IEC 60947-2, carries IP40 per IEC 60529, IK07 per IEC 62262, and is suitable for isolation per the same standard. Pollution degree 3 per IEC 60664-1. RoHS and REACH compliance documentation is typically included with the product — confirm with the supplier at order.