Skip to main content
Schneider Electric C10F6TM100C — Molded Case Circuit Breakers (MCCB)

Schneider Electric C10F6TM100C ComPacT NSX100F MCCB, 100 A,

MPNC10F6TM100C
Active

Schneider Electric ComPacT NSX, NSX100F, circuit breaker, 100 A at 50 °C, TM-D trip unit, 4P, 36 kA Icu at 415 V AC, IP40.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C10F6TM100C — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
C10F6TM100C — Electrical
ParameterValue
[In] rated current100 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz
C10F6TM100C — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameNSX100F
StandardsEN/IEC 60947-2

Product details

The TM-D trip combines a thermal bimetal for overload protection (L) and a magnetic coil for short-circuit protection (I), both adjustable on the trip unit. At 220/240 V it handles 85 kA; at 690 V it drops to 8 kA — the voltage derating is steep, so verify the available fault current at your system voltage. The breaker is 4-pole (4P) with the neutral on the left, configured for 3D neutral protection (no protection on the neutral pole). Mounting is backplate, horizontal or vertical, with front connections top and bottom.

Frequently asked questions

What is the breaking capacity of C10F6TM100C at 415 V?

The breaking capacity is 36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, which corresponds to the F breaking capacity code.

Where can I buy C10F6TM100C?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider Electric provide for C10F6TM100C?

The breaker is certified to EN/IEC 60947-2, carries IP40 per IEC 60529, IK07 per IEC 62262, and is suitable for isolation per the same standard. Pollution degree 3 per IEC 60664-1. RoHS and REACH compliance documentation is typically included with the product — confirm with the supplier at order.

MPN
C10F6TM100C