Skip to main content
Schneider Electric C10N1TM016

Schneider Electric C10N1TM016

MPNC10N1TM016
Active

Circuit breaker, ComPacT NSX100N AC/DC, 25kA/240VAC, 1 pole, TMD trip unit 16A

$83.16Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C10N1TM016 key specifications
ParameterValue
Control typeToggle
Network typeAC DC
Protection typeL : for overload protection (thermal) I : for short-circuit protection (magnetic)
Product or component typeCircuit breaker
Long-time protection delay adjustment type trFixed
Instantaneous protection pick-up adjustment type iiFixed
Long-time pick-up adjustment type ir (thermal protection)Fixed
Voltage750 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage277 V AC 50/60 Hz 250 V DC
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
Breaking capacity25 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 250 V DC conforming to IEC 60947-2
Current16 A at 40 °C

All specifications

C10N1TM016 additional specifications
ParameterValue
Breaking capacity codeN 25 kA 240 V AC
[Ics] rated service breaking capacity25 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 250 V DC conforming to IEC 60947-2
Power dissipation per pole2.92 W
Network frequency50/60 Hz
Poles description1P
Protected poles description1D
Utilisation categoryCategory A
IK degree of protectionIK07 conforming to IEC 62262
IP degree of protectionIP40 conforming to IEC 60529
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Circuit breaker mounting modeFixed
Connection pitch35 mm
Upside connectionFront
Downside connectionFront
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
Electrical shock protection classClass II on front face
Depth86 mm
Width35 mm
Height161 mm
Electrical durability20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical durability20000 cycles
StandardsEN/IEC 60947-2
RangeComPacT
Trip unit nameTM-D
Trip unit rating16 A at 40 °C
Device short nameNSX100N
Device applicationDistribution
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Trip unit protection functionsLI
Ambient air temperature for storage-50...85 °C
Ambient air temperature for operation-25...70 °C
[Ir] long-time protection pick-up adjustment range1 x In
[Ii] instantaneous protection pick-up adjustment range190 A
MPN