Skip to main content
Schneider Electric C10W4TM100 — Miniature Circuit Breakers (MCB)

Schneider Electric C10W4TM100 ComPacT NSX 100A 4P Thermal-Ma

MPNC10W4TM100
Active

Schneider Electric ComPacT NSX, circuit breaker, 100 A, 4P, thermal-magnetic TM-D trip unit, 100 kA Icu at 690 V AC, breaking capacity code HB2.

$7.75Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10W4TM100 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10W4TM100 — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10W4TM100 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C10W4TM100 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10W4TM100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10W4TM100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10W4TM100 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C10W4TM100 is a ComPacT NSX circuit breaker with a thermal-magnetic TM-D trip unit, rated 100 A at 40 °C, 4 poles, and a breaking capacity of 100 kA Icu at 690 V AC (HB2 code). It's designed for distribution applications and meets EN/IEC 60947-2.

The 161 x 140 x 86 mm envelope (H x W x D) fits standard panel cutouts for the NSX100 frame. Front connections both top and bottom simplify busbar routing. Toggle control, horizontal or vertical mounting allowed — flat on the back.

Frequently asked questions

What is the breaking capacity of C10W4TM100?

100 kA Icu at 500 V, 525 V, and 660/690 V AC 50/60 Hz per IEC 60947-2, with breaking capacity code HB2.

What standards does C10W4TM100 comply with?

EN/IEC 60947-2, pollution degree 3 per IEC 60664-1, overvoltage category III, and suitability for isolation per EN/IEC 60947-2.

Where can I buy C10W4TM100 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
C10W4TM100