Schneider Electric ComPacT NSXm, C11B3TM016B, 3P, 16 A at 40 °C, TM-D trip unit, 25 kA 415 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11B3TM016B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11B3TM016B — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11B3TM016B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11B3TM016B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches9 module
C11B3TM016B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11B3TM016B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11B3TM016B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
C11B3TM016B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The 3-pole configuration (3P) suits three-phase distribution panels. The thermal-magnetic trip unit (TM-D) is a fixed-setting type, not adjustable in the field, so the 16 A rating must match the protected circuit's design current.

Deployment context

Mounts on a backplate (DIN rail compatible via the 9-module pitch) in a distribution panel or enclosure. The IP40 front face and IK07 impact resistance suit indoor panel installations where tools or panels may be bumped. Connection is via compression lugs or busbars, front-accessible from both top and bottom. The 35 mm connection pitch with spreaders (27 mm without) matches standard busbar systems. The toggle control and green flag for auxiliary contact presence give clear local status.

Frequently asked questions

Where can I buy C11B3TM016B and how do I get a price?

This part is sourced and quoted to order against an RFQ. Submit a request through the storefront; availability and current pricing are confirmed at quote time.

What is the breaking capacity of C11B3TM016B?

The breaking capacity is 25 kA at 415 V AC, performance level B per EN/IEC 60947-2.

What standards does C11B3TM016B comply with?

It complies with EN/IEC 60947-2 and is suitable for isolation per that standard. Pollution degree 3 and overvoltage category III are rated per IEC 60664-1.

What is the rated current of C11B3TM016B?