Skip to main content
Schneider Electric C11E3TM025L — Miniature Circuit Breakers (MCB)

Schneider C11E3TM025L ComPacT NSXm 25A 3P MCCB, 16 kA 415V

MPNC11E3TM025L
Active

Schneider Electric ComPacT NSXm, C11E3TM025L, 3-pole MCCB, 25 A thermal-magnetic TM-D trip unit, 16 kA at 415 V AC, EN/IEC 60947-2.

$216.66Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11E3TM025L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11E3TM025L — Ratings
ParameterValue
Rated current (In)25 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11E3TM025L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11E3TM025L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches9 module
C11E3TM025L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11E3TM025L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11E3TM025L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
C11E3TM025L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The EN/IEC 60947-2 listing certifies it as a molded-case circuit breaker for isolation and overcurrent protection, not just a supplementary protector.

At 81 mm wide and 137 mm tall, it occupies 9 module pitches on a DIN-rail assembly. The front-facing Everlink lugs accept 2.5–95 mm² rigid or stranded copper/aluminium and 2.5–70 mm² flexible copper — sized for the 25 A feed. IK07 handles accidental tool strikes during panel work.

No last-time-buy window to watch.

Frequently asked questions

What is the interrupting rating of C11E3TM025L?

The performance level is 16 kA at 415 V AC, which is the interrupting capacity for this 3-pole MCCB under standard distribution duty.