Specifications

C11E3TM032L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11E3TM032L — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11E3TM032L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11E3TM032L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches9 module
C11E3TM032L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11E3TM032L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11E3TM032L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
C11E3TM032L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C11E3TM032L is a ComPacT NSXm 3-pole thermal-magnetic circuit breaker rated 32 A at 40 °C, with a breaking capacity of 16 kA at 415 V AC. It's built to EN/IEC 60947-2, which covers the performance and testing for low-voltage switchgear — so you know it's certified for distribution and motor-circuit protection in commercial and industrial panels. The 32 A TM-D trip unit gives you a fixed thermal-magnetic curve, no interchangeable trip blocks, which keeps the BOM simple and the spare parts count low.

Category A utilisation means it's not intended for selectivity under short-circuit conditions with other breakers — it's a standalone protector for a branch circuit. The 3.3 W power dissipation per pole adds up to about 10 W total; make sure your enclosure has enough ventilation to keep the internal temperature rise within limits.

Front-facing connections on both line and load sides; the Everlink lug terminals accept 2.5 to 95 mm² rigid aluminium/copper or 2.5 to 70 mm² flexible copper. That's a wide wire range — you can land a 10 mm² feeder or a 70 mm² main on the same lug without adapters. The 35 mm connection pitch with spreaders (27 mm without) lets you manage phase spacing in a crowded enclosure.