Skip to main content
Schneider Electric C11H4TM032L — Miniature Circuit Breakers (MCB)

Schneider Electric C11H4TM032L ComPacT NSXm 32A 4P Circuit B

MPNC11H4TM032L
Active

Schneider Electric ComPacT NSXm, 4P, 32 A, 70 kA at 415 V AC, thermal-magnetic trip unit TM-D, grey (RAL 7016).

$371.60Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11H4TM032L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11H4TM032L — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11H4TM032L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11H4TM032L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11H4TM032L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11H4TM032L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11H4TM032L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11H4TM032L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C11H4TM032L is a ComPacT NSXm 4-pole moulded-case circuit breaker rated 32 A at 40 °C, with a thermal-magnetic TM-D trip unit. It carries a 70 kA interrupting capacity at 415 V AC (performance level H), so it clears high-fault currents on a distribution board without upstream coordination issues — the IEC 60947-2 Category A utilisation means it is not intended for selective coordination downstream of another breaker, but it isolates reliably (suitability for isolation confirmed).

The 108 mm width occupies 12 modules of 9 mm pitch — plan the DIN-rail or busbar layout accordingly. Terminals are front-facing Everlink lugs accepting 2.5…95 mm² rigid or stranded aluminium/copper (70 mm² flexible copper).

Frequently asked questions

What is the breaking capacity of C11H4TM032L?

It is rated 70 kA at 415 V AC (performance level H), which means it can safely interrupt fault currents up to that level without damage to downstream equipment.

How do I get current pricing and availability for C11H4TM032L?

Submit an RFQ through the storefront — availability and current pricing are confirmed at quote time against your quantity and delivery requirements.

What compliance documentation does this brand provide for C11H4TM032L?

The breaker is certified to EN/IEC 60947-2 and carries suitability for isolation per that standard. IP40 and IK07 protection degrees are listed; pollution degree 3 per IEC 60664-1 is specified.

MPN
C11H4TM032L