Schneider Electric C125H45EFM — Miniature Circuit Breakers (MCB)

C125H45EFM ComPacT NS 1250A 4P MCCB, MicroLogic 5.0 E, 70 kA

MPNC125H45EFM
Active

Schneider Electric ComPacT NS new generation, C125H45EFM, 4-pole MCCB, 1250 A, MicroLogic 5.0 E trip unit, 70 kA Icu at 415 V AC, fixed mount, LCD display, energy meter.

$3,842.71Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C125H45EFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C125H45EFM — Ratings
ParameterValue
Rated current (In)1250 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C125H45EFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C125H45EFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C125H45EFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C125H45EFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C125H45EFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

Schneider Electric C125H45EFM is a 4-pole fixed-mount ComPacT NS new generation MCCB. Rated 1250 A at 50 °C with a MicroLogic 5.0 E electronic trip unit that includes an integrated energy meter — the E suffix means it measures and reports energy consumption directly through the trip unit's LCD display. Breaking capacity is 70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, with a code H designation. At 220/240 V it reaches 85 kA Icu, and at 660/690 V it holds 42 kA Icu. The trip unit provides L (long-time overload), S (short-time short-circuit), and I (instantaneous) protection curves, plus a 20-minute thermal memory. That thermal memory prevents nuisance tripping on reclose after a brief overload — the breaker remembers the previous thermal state and adjusts the curve so it doesn't trip too early on a second start.

Fixed backplate mount, 327 mm high × 280 mm wide × 147 mm deep. Front connections both top and bottom — wire entry and busbar landing on the same face, which simplifies panel layout. Connection pitch is 70 mm, standard for this frame size. IP40 enclosure protection, IK07 impact resistance. Manually operated with an LCD display showing measured values and fault codes — four red LEDs for fault indication, one yellow for overload. Neutral on the left. Rated for 0–2000 m altitude without derating; above that up to 5000 m with derating. 0–95 % relative humidity range.

Frequently asked questions

What breaking capacity does C125H45EFM have at 415 V?

70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. The H breaking capacity code designates this level. At 220/240 V it reaches 85 kA Icu, and at 660/690 V it holds 42 kA Icu.

What trip unit does C125H45EFM use?

MicroLogic 5.0 E electronic trip unit with L (overload), S (short-time short-circuit), and I (instantaneous) protection. The E suffix adds integrated energy metering displayed on the LCD. Trip rating is 1250 A at 50 °C.

What compliance standards does C125H45EFM meet?

Designed and tested to EN/IEC 60947-2. Rated for pollution degree 3 and overvoltage category III. IP40 enclosure, IK07 impact resistance. Altitude rating 0–2000 m without derating, up to 5000 m with derating.

MPN
C125H45EFM