Skip to main content
Schneider Electric C125H4WM — Miniature Circuit Breakers (MCB)

C125H4WM ComPacT NS1250H Basic Frame, 1250 A, 70 kA at 415 V

MPNC125H4WM
Active

Schneider Electric ComPacT NS1250H new generation, basic frame C125H4WM, 1250 A at 50 °C, 70 kA Icu at 415 VAC, 4 poles, withdrawable, manually operated, without control unit.

$3,538.56 – $7,515.72Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C125H4WM — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeBasic frame
Device applicationDistribution
C125H4WM — Ratings
ParameterValue
Rated current (In)1250 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C125H4WM — Protection
ParameterValue
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2 3000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 4000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 5000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2
Mechanical durability (cycles)10000 cycles conforming to IEC 60947-2
C125H4WM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeWithdrawable
Control typeManually operated
C125H4WM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
C125H4WM — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The C125H4WM is the basic frame of the ComPacT NS1250H new generation — a 1250 A rated current at 50 °C and a 70 kA Icu at 415 V AC define its fault-clearing ceiling. The 4-pole configuration with neutral on the left is the standard for three-phase plus neutral distribution. It is a basic frame — no control unit, no integral protection beyond the 40 kA integral instant protection. You add the trip unit separately to match your load's protection curve. Withdrawable mounting means the frame slides out of its cradle for inspection or swap without disturbing the bus connections — a real time-saver in a turnaround where every minute counts. Manually operated, so no motor operator for remote closing; if your BOM needs remote control, factor in the optional motor mechanism. The IP40 and IK07 ratings mean it is protected against tools and wires over 1 mm and impact energy of 2 J — standard for enclosed switchboard installation, not for open panel fronts.

Mounts on a backplate in a fixed or withdrawable cradle. The 306 mm width, 260 mm height, 147 mm depth and 70 mm connection pitch are what you need to check against your switchboard cutout and busbar spacing.

Certified to IEC 60947-2 for low-voltage switchgear and controlgear. Suitability for isolation is confirmed — it can be used as a disconnector under that standard. Class II on the front face means no protective earth connection needed on the operator interface. The manufacturer provides the standard compliance documentation (declaration of conformity, IEC test reports) upon request.

Frequently asked questions

How do I get current pricing and availability for C125H4WM?

We source and quote the C125H4WM to order against an RFQ. Send the request and we confirm availability and current pricing at quote time.

What is the closest alternative to C125H4WM in the ComPacT family?

The closest sibling is the fixed-version basic frame (C1254FWM) — same 1250 A rating and 70 kA Icu at 415 V, but fixed mounting instead of withdrawable. If your panel design uses a fixed cradle, that frame saves cost; if you need slide-out for maintenance, stick with the withdrawable C125H4WM.

What is C125H4WM's listed range?

The range is ComPacT NS630b...1600 new generation, covering frames from 630 A to 1600 A.

What compliance documentation does Schneider provide for C125H4WM?

The frame is certified to IEC 60947-2 and carries suitability for isolation per that standard. The manufacturer supplies the declaration of conformity and IEC type-test reports on request.

MPN
C125H4WM