Schneider Electric C125N4WM — Molded Case Circuit Breakers (MCCB)

Schneider Electric C125N4WM ComPacT NS1250N 1250A 4P Withdra

MPNC125N4WM
Active

Schneider Electric ComPacT NS1250N new generation, basic frame C125N4WM, 1250 A at 50 °C, 50 kA Icu at 415 V AC, 4P, withdrawable, manually operated, without control unit.

$2,577.67 – $6,634.44Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C125N4WM — Identification
ParameterValue
Product / component typeBasic frame
Device applicationDistribution
C125N4WM — Ratings
ParameterValue
Number of poles4P
C125N4WM — Electrical
ParameterValue
[In] rated current1250 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
C125N4WM — Specifications
ParameterValue
StandardsIEC 60947-2

Product details

The C125N4WM is a basic frame from the Schneider Electric ComPacT NS630b...1600 new generation range — a manually operated, withdrawable 4-pole unit rated 1250 A at 50 °C.

Mounts withdrawable on a backplate with a 70 mm connection pitch. The 306 mm width and 260 mm height mean it fills a standard panel cubicle opening; depth is 147 mm. Neutral sits on the left.

Frequently asked questions

What is the C125N4WM rated breaking capacity at 415 V AC?

50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. The Ics (service breaking capacity) at the same voltage is also 50 kA, meaning it can reclose and carry rated current after a fault at that level without derating.

Where can I buy the C125N4WM?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock count or lead-time number is held on this page.

MPN