C12N6TM125B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C12N6TM125B — Ratings
ParameterValue
Rated current (In)125 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C12N6TM125B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C12N6TM125B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C12N6TM125B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C12N6TM125B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C12N6TM125B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C12N6TM125B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

It is a 4-pole (4P) device, designed for distribution applications per EN/IEC 60947-2.

Mounts on a backplate in either horizontal or vertical orientation, flat on the back. The 108 mm width and 137 mm height fit standard enclosure cutouts; depth is 80 mm. Connection terminals accept compression lugs or busbars, with front-facing upside and downside connections for straightforward panel wiring. Neutral is on the left.

Frequently asked questions

What is the breaking capacity of C12N6TM125B?

The C12N6TM125B has a performance level of N, meaning 50 kA at 415 V AC. That is the maximum fault current it can safely interrupt at that voltage.

Where can I buy C12N6TM125B?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current availability and pricing.

What standards does C12N6TM125B comply with?

It complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear. It is also suitable for isolation per that standard.

MPN
C12N6TM125B