Schneider Electric C163MG160D — Miniature Circuit Breakers (MCB)

C163MG160D ComPacT NSX160 DC Trip Unit, 160A, 750VDC

MPNC163MG160D
Active

Schneider Electric ComPacT NSX160 DC, C163MG160D, 3-pole thermal-magnetic trip unit, 160 A at 40 °C, 750 V DC, LI protection, generator application.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C163MG160D — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250 DC
Product/component typeTrip unit
Device applicationGenerator
C163MG160D — Ratings
ParameterValue
Poles configuration3P
Rated operational voltage (Ue)750 V DC
Network type (AC/DC)DC
C163MG160D — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
C163MG160D — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C163MG160D — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C163MG160D — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C163MG160D is a TM-G thermal-magnetic trip unit for the ComPacT NSX100...250 DC range, rated 160 A at 40 °C with a 750 V DC maximum operating voltage. It protects a 3-pole DC circuit (3D protected poles) with LI protection: thermal overload (L) via a fixed long-time delay and adjustable pick-up from 0.7 to 1 x In, plus magnetic short-circuit (I) with a fixed instantaneous pick-up of 530 A. The trip unit is designed specifically for generator applications, per the device application field. Rated operational voltage of 750 V DC means this unit handles the higher DC bus voltages common in generator output circuits, UPS systems, and solar combiner boxes — not a standard 24 V or 48 V DC control circuit. The 530 A instantaneous magnetic trip (fixed, non-adjustable) clears hard faults fast, while the adjustable thermal element (0.7–1 x In) lets you dial in the continuous current threshold for the specific generator nameplate.

IP40 front face protection keeps tools and fingers out but is not washdown-rated. Electrical shock protection Class II — double-insulated, no earth connection required on the trip unit itself.

Frequently asked questions

Where can I buy C163MG160D and how do I get a price?

C163MG160D is sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability confirmation at quote time.

What are the key ratings for C163MG160D?

Rated 160 A at 40 °C, 750 V DC maximum operating voltage, 3-pole (3D protected poles), thermal-magnetic LI protection with fixed instantaneous pick-up at 530 A and adjustable long-time pick-up from 0.7 to 1 x In.

What standard does C163MG160D comply with?

It complies with EN/IEC 60947-2 for low-voltage switchgear and circuit-breakers, with pollution degree 3 per IEC 60947-1.