Schneider Electric ComPacT NSX series, C25F4TM160C, 4P 160A thermal-magnetic MCCB, 36 kA Icu at 415 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25F4TM160C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25F4TM160C — Ratings
ParameterValue
Rated current (In)160 A at 50 °C
Poles configuration4P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25F4TM160C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25F4TM160C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C25F4TM160C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25F4TM160C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25F4TM160C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C25F4TM160C is a ComPacT NSX250F frame 4-pole MCCB rated 160 A at 50 °C with a thermal-magnetic TM-D trip unit. The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection per the curve, with the magnetic pickup fixed at a multiple of In — no electronic adjustment, so the coordination study must respect that fixed threshold. Breaking capacity is the headline selection parameter: 85 kA Icu at 240 V AC, 36 kA Icu at 415 V AC, and 30 kA at 500 V AC, all per IEC 60947-2.

Mounts on a backplate in horizontal or vertical orientation. Front connection for both line and load sides. The 140 mm width, 161 mm height, and 86 mm depth fit standard NSX cutouts in panel layouts. IP40 enclosure protection and IK07 impact resistance are adequate for indoor switchboard installation; outdoor or washdown environments require an additional enclosure.

Frequently asked questions

How do I get current pricing and availability for C25F4TM160C?

Current pricing and availability are confirmed at quote time. Submit an RFQ against this order code; the quoted price and lead time reflect the prevailing market conditions through independent distribution channels.

What is the breaking capacity of C25F4TM160C at 415 V?

The breaking capacity is 36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. This is the F breaking capacity code, suitable for standard industrial distribution where the prospective fault current does not exceed 36 kA.

What compliance documentation does this brand provide for C25F4TM160C?

The breaker is certified to EN/IEC 60947-2 and carries suitability for isolation per that standard. The manufacturer typically provides a Declaration of Performance (DoP) and CE declaration. RoHS and REACH compliance documentation is available on request from the manufacturer's documentation portal.