Schneider Electric C25F4TM160 — Miniature Circuit Breakers (MCB)

Schneider C25F4TM160 ComPacT NSX250F MCCB, 160 A, 36 kA 415

MPNC25F4TM160
Active

Schneider Electric ComPacT NSX, NSX250F, MCCB, 4P, 160 A, TM-D trip unit, 36 kA Icu at 415 V AC, IP40, toggle control.

$545.92Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25F4TM160 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25F4TM160 — Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Poles configuration4P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25F4TM160 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25F4TM160 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C25F4TM160 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25F4TM160 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25F4TM160 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C25F4TM160 is a Schneider Electric ComPacT NSX250F moulded-case circuit breaker — a 4-pole, 160 A thermal-magnetic MCCB built to EN/IEC 60947-2 for distribution duty. The TM-D trip unit gives you L (thermal overload) and I (magnetic short-circuit) protection in one block, no add-on modules needed for basic feeder or main-switch applications.

The utilisation category is A, meaning it's not intended for cascading (no deliberate short-time delay for selectivity with downstream devices). If you need selective coordination with a downstream breaker, you'd step to a category B MCCB.

Panel integration — mounting and connections

Front-facing connections top and bottom make wiring straightforward in a dead-front enclosure. The toggle handle gives clear visual indication of tripped vs ON/OFF state, and the IP40 enclosure keeps dust out in clean indoor panels.

Trip unit and protection settings

Overload (thermal) curve tracks I²t; the magnetic short-circuit pickup is non-adjustable on this trip unit — typically around 10× In for TM-D. Neutral protection is set at 1× Ir (full rated current), with the neutral pole on the left.

Durability and environmental limits

Mechanical endurance is 20,000 cycles; electrical durability at full rated current (440 V In) is 10,000 cycles — halve the load and it doubles to 20,000 cycles. Operating altitude is 0–2000 m without derating; above that up to 5000 m requires derating per the manufacturer's curve. Relative humidity range is 0–95 %, and the enclosure carries IK07 impact protection per IEC 62262.

Frequently asked questions

Where can I buy C25F4TM160 and how do I get a price?

The C25F4TM160 is available to order through independent industrial-automation distribution. Submit an RFQ for current pricing and lead-time confirmation — availability is confirmed at quote time.

What is the closest alternative to C25F4TM160 in the ComPacT family?

Within the same NSX250F frame, the closest alternative would be a unit with a different trip rating or a Micrologic electronic trip if you need adjustable short-time pickup or ground-fault protection. The C25F4TM160 uses a fixed thermal-magnetic TM-D trip; stepping to a Micrologic 2.2 or 5.2 adds selectivity and communication options but changes the trip-unit order code.

What compliance documentation does Schneider provide for C25F4TM160?

The breaker is designed and certified to EN/IEC 60947-2. It carries CE marking for the European market. For specific RoHS, REACH, or UL documentation, consult the product certificate available through Schneider's documentation portal or request it with your RFQ.

MPN