Schneider Electric C4042B400 — Miniature Circuit Breakers (MCB)

Schneider C4042B400 MicroLogic 2.3 AB Trip Unit, 400 A, 4P

MPNC4042B400
Active

Schneider Electric, ComPacT NSX series, MicroLogic 2.3 AB electronic trip unit, order code C4042B400, 400 A at 40 °C, 4 poles, LSoI protection, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C4042B400 — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX400...630
Product/component typeTrip unit
Device applicationSpecial application
C4042B400 — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C4042B400 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
C4042B400 — Mechanical
ParameterValue
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C4042B400 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C4042B400 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C4042B400 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range260...400 A
Trip unit protection functionsLSoI

Product details

The Schneider Electric C4042B400 is a MicroLogic 2.3 AB electronic trip unit for the ComPacT NSX400...630 range. It's rated 400 A at 40 °C, 4 poles (4D), and built to EN/IEC 60947-2. The LSoI protection package covers long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I).

The short-time pickup (Isd) has nine adjustable settings from 1.5 to 10 x Ir — that's selectivity headroom for downstream breakers. Instantaneous (Ii) is fixed at 4800 A, which clears a hard fault fast. The thermal memory holds a 20-minute pre- and post-trip record, so re-energizing a hot circuit won't nuisance-trip on the second hit.

Mounts fixed in the ComPacT NSX400...630 breaker frame. Neutral position is left; neutral protection settings cover 3D + N/2, 4D, or 3D (no neutral protection). The pollution degree is 3 per IEC 60947-1, so it's fine for industrial panels with moderate conductive dust.

Frequently asked questions

What are the key ratings of the C4042B400 trip unit?

Rated 400 A at 40 °C, 4 poles, 690 V AC, LSoI protection. Long-time pickup adjustable 260–400 A, short-time pickup adjustable 1.5–10 x Ir, instantaneous fixed at 4800 A.

Where can I buy C4042B400 and get current pricing?