Schneider Electric C4044B400 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C4044B400 ComPacT NSX Trip Unit, MicroLog

MPNC4044B400
Active

Schneider Electric ComPacT NSX400...630, MicroLogic 4.3 AB electronic trip unit, 400 A at 40 °C, 4P, integrated earth-leakage protection, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C4044B400 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload Color indicator (yellow) for residual current
C4044B400 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
C4044B400 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C4044B400 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C4044B400 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C4044B400 is a MicroLogic 4.3 AB electronic trip unit for the ComPacT NSX400...630 range, rated 400 A at 40 °C. It sits in a 4P fixed-mount breaker and carries integrated earth-leakage protection (Class A). The EN/IEC 60947-2 standard governs its short-circuit and coordination performance — that's the standard for low-voltage switchgear and controlgear, so the unit is designed for selective coordination in distribution panels. The long-time pickup (Ir) is adjustable from 260 to 400 A — that's the overload threshold. Short-time pickup (Isd) adjusts 1.5 to 10 x Ir, giving you a wide band for motor or feeder coordination. Instantaneous pickup (Ii) is fixed at 4800 A, which means it clears hard faults above that level without delay. Earth-leakage sensitivity (IΔn) and time delay (Δt) are both adjustable via the rotary switch on the front face. You can set neutral protection to 0.5 x Ir (3D + N/2), 1 x Ir (4D), or no protection (3D) — the protected poles description matches: 3D + N/2, 4D, or 3D.

Integration notes — panel fit and wiring

Fixed-mount breaker, 4P, neutral on the left. Pollution degree 3 per IEC 60947-1 — that's the typical industrial environment with conductive pollution, so no extra conformal coating needed in a standard IP40 enclosure. Network frequency is 50/60 Hz, rated operational voltage 440 V AC.

Frequently asked questions

What is C4044B400's listed range and standards?

It belongs to the ComPacT NSX400...630 range and complies with EN/IEC 60947-2.

What protection functions does the MicroLogic 4.3 AB trip unit provide?

It provides L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage) protection.

MPN
C4044B400