miniature circuit breaker - C60HB - 3 poles - 2 A - B curve BSEN

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60HB302 key specifications
ParameterValue
Control typeToggle
Network typeAC DC
Product or component typeMiniature circuit-breaker
Voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage12...440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Current2 A at 30 °C
[Ics] rated service breaking capacity7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Network frequency50/60 Hz
Poles description3P
Number of protected poles3

All specifications

C60HB302 additional specifications
ParameterValue
Mounting modeFixed
Mounting support35 mm symmetrical DIN rail
Connections - terminalsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Relative humidity95 % at 55 °C
Operating altitude2000 m
Depth73 mm
Width54 mm
Height81 mm
Mechanical durability20000 cycles
StandardsEN 60898 IEC 60947-2
RangeMulti9
Curve codeB
9 mm pitches6
Tropicalisation2 conforming to IEC 60068-1
Limitation class3 conforming to IEC 60947-2
Local signallingON/OFF indication
Device short nameC60H
Tightening torquePower circuit: 2 N.m upside 2 N.m downside
Device applicationDistribution
Trip unit technologyThermal-magnetic
Magnetic tripping limit3...5 x In
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to IEC 60947-2
Contact position indicatorYes
Ambient air temperature for storage-40...70 °C
Ambient air temperature for operation-25...60 °C
Comb busbar and distribution block compatibilityNO
MPN