Skip to main content
Schneider Electric C60HC10R100 — Residual Current Breakers (RCCB/RCBO)

C60HC10R100 C60H RCBO 1P+N 10A C-Curve 10kA, Obsolete

MPNC60HC10R100
Obsolete

Schneider Electric C60H series RCBO, 1 pole + neutral, 10 A rated current, C-curve, 10 kA breaking capacity, thermal-magnetic trip, 100 mA earth leakage sensitivity, instantaneous time delay.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60HC10R100 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeClass AC
Earth-leakage trip time delayInstantaneous
Trip unit technologyThermal-magnetic
Local signalling / indicationPositive break indication
C60HC10R100 — Electrical Ratings
ParameterValue
Rated current (In)10 A at 30 °C
Rated operational voltage (Ue)50...250 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionRight
Network typeAC
Network frequency50/60 Hz
Device location in systemOutgoer
Electrical durability20000 cycles
C60HC10R100 — Identification
ParameterValue
Device short nameC60H RCBO
C60HC10R100 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminals (downstream) 10 mm² flexible Tunnel type terminals (downstream) 16 mm² rigid Tunnel type terminals (upstream) 16 mm² flexible Tunnel type terminals (upstream) 25 mm² rigid
Terminal tightening torque2 N.m
C60HC10R100 — Environmental
ParameterValue
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2
C60HC10R100 — Approvals
ParameterValue
StandardsIEC 1009-2-2

Product details

The C60HC10R100 is a C60H series RCBO from Schneider Electric — a combined miniature circuit breaker and residual current device in a 1-pole + neutral format. Earth-leakage protection is built in — 100 mA sensitivity, Class AC, instantaneous trip. That makes it suited for general-purpose socket circuits or lighting final circuits where 30 mA personal protection isn't required, but equipment and fire protection is. The thermal-magnetic trip unit handles overloads and short-circuits; the residual current module handles ground faults.

The neutral is on the right side of the module. Positive break indication on the toggle gives a visual confirmation that the contacts are physically open.

Environmental and operational limits

Electrical durability is rated at 20,000 cycles. The tropicalisation treatment (class 2) adds some resistance to heat and humidity, which matters if the panel sits in an unconditioned space.

Frequently asked questions

Where can I buy C60HC10R100 and how do I get a price?

This RCBO is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is C60HC10R100's listed standards (IEC 1009-2-2) on this component line?

The C60HC10R100 is designed and tested to IEC 1009-2-2, the standard for residual current operated circuit breakers with integral overcurrent protection (RCBOs). It also meets the limitation class 3 requirements of EN 60898 for energy-limiting performance.

What is C60HC10R100's listed curve code (C) on this component line?

The C-curve means the magnetic trip operates between 5 and 10 times the rated current (In). For a 10 A device, that's a magnetic trip window of 50 to 100 A — suitable for circuits with moderate inrush, like small motors, fluorescent lighting, or transformer loads.

MPN
C60HC10R100