Schneider Electric C60HC16R30 — Residual Current Breakers (RCCB/RCBO)

C60HC16R30 C60H RCBO, 16 A, C-Curve, 10 kA, Obsolete

MPNC60HC16R30
Obsolete

Schneider Electric C60H RCBO, 1 pole + N, 16 A, C-curve, 10 kA breaking capacity, 30 mA earth leakage, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60HC16R30 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeClass AC
Earth-leakage trip time delayInstantaneous
Trip unit technologyThermal-magnetic
Local signalling / indicationPositive break indication
C60HC16R30 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)50...250 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionRight
Network typeAC
Network frequency50/60 Hz
Device location in systemOutgoer
Electrical durability20000 cycles
C60HC16R30 — Identification
ParameterValue
Device short nameC60H RCBO
C60HC16R30 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminals (downstream) 10 mm² flexible Tunnel type terminals (downstream) 16 mm² rigid Tunnel type terminals (upstream) 16 mm² flexible Tunnel type terminals (upstream) 25 mm² rigid
Terminal tightening torque2 N.m
C60HC16R30 — Environmental
ParameterValue
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2
C60HC16R30 — Approvals
ParameterValue
StandardsIEC 1009-2-2

Product details

The C60HC16R30 is a C60H-series residual-current circuit breaker with overcurrent protection (RCBO), combining a 16 A thermal-magnetic MCB and a 30 mA earth-leakage module in a single 1P+N unit. It carries a C-curve magnetic trip of 5–10 × In, so it handles moderate inrush from motorised or capacitive loads without nuisance tripping, and its 10 kA breaking capacity at 50–250 V AC (IEC 1009) means it can safely interrupt a bolted fault up to that level — provided the upstream device coordinates. The earth-leakage protection is instantaneous, Class AC, suited for sinusoidal residual currents in distribution final circuits.

The neutral is on the right. The positive-break indication gives a visible gap on the toggle when the contacts are open — useful during lockout/tagout.

Frequently asked questions

Where can I buy C60HC16R30 and how do I get a price?

We source the C60HC16R30 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What is C60HC16R30's listed standards (IEC 1009-2-2) on this component line?

The C60HC16R30 is designed to IEC 1009-2-2, the standard for residual-current operated circuit breakers with integral overcurrent protection (RCBOs).

What is C60HC16R30's listed curve code (C) on this component line?

The C60HC16R30 has a C-curve, meaning its magnetic trip operates between 5 and 10 times the rated current (16 A), so it tolerates moderate inrush from motor or capacitor loads without tripping.