Schneider Electric C60HC20R100 — Residual Current Breakers (RCCB/RCBO)

C60HC20R100 C60H RCBO, 20 A C-Curve, 10 kA, Obsolete

MPNC60HC20R100
Obsolete

Schneider Electric C60H RCBO, 1 pole + N, 20 A, C curve, 100 mA earth leakage, 10 kA breaking capacity, thermal-magnetic trip, 50-250 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60HC20R100 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeClass AC
Earth-leakage trip time delayInstantaneous
Trip unit technologyThermal-magnetic
Local signalling / indicationPositive break indication
C60HC20R100 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 30 °C
Rated operational voltage (Ue)50...250 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionRight
Network typeAC
Network frequency50/60 Hz
Device location in systemOutgoer
Electrical durability20000 cycles
C60HC20R100 — Identification
ParameterValue
Device short nameC60H RCBO
C60HC20R100 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminals (downstream) 10 mm² flexible Tunnel type terminals (downstream) 16 mm² rigid Tunnel type terminals (upstream) 16 mm² flexible Tunnel type terminals (upstream) 25 mm² rigid
Terminal tightening torque2 N.m
C60HC20R100 — Environmental
ParameterValue
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2
C60HC20R100 — Approvals
ParameterValue
StandardsIEC 1009-2-2

Product details

The C60HC20R100 is a C60H-series RCBO (residual current circuit breaker with overcurrent protection) from Schneider Electric — 1 pole + N, rated 20 A at 30 °C, C-curve magnetic trip (5 to 10 × In), with 100 mA earth-leakage sensitivity (Class AC, instantaneous). It breaks up to 10 kA Icu at 50–250 V AC, 50/60 Hz, per IEC 1009-2-2.

The C curve (5–10 × In) means the magnetic trip fires between 100 A and 200 A — designed for mixed resistive-inductive loads like small motor circuits, lighting banks, and control transformers where inrush is moderate but not as high as a D-curve would handle. The 100 mA earth-leakage threshold is for equipment protection, not personnel shock protection (that needs 30 mA or lower); it catches insulation faults before they escalate to a phase-to-ground short. Thermal-magnetic trip technology combines a bimetal strip for overload protection (time-delayed, inverse-time) and a solenoid for short-circuit protection (instantaneous above the magnetic threshold). The 20 A rating at 30 °C ambient means the thermal element tracks load current; derate for higher ambient temperatures per the manufacturer's curve.

Deployment context

The 1P+N format (switched phase, solid neutral) is typical for single-phase outgoing circuits in TN or TT earthing systems.

Schneider Electric lists the C60HC20R100 as obsolete.

Frequently asked questions

What is C60HC20R100's listed standards (IEC 1009-2-2) on this component line?

The C60HC20R100 is designed and tested to IEC 1009-2-2, the standard for residual current operated circuit breakers with integral overcurrent protection (RCBOs).