Schneider Electric C60HC45R100 — Residual Current Breakers (RCCB/RCBO)

C60HC45R100 C60H RCBO, 1P+N, 45A, C-curve, 100mA, obsolete

MPNC60HC45R100
Obsolete

Schneider Electric C60H RCBO, 1 pole + neutral, 45 A, C curve, 100 mA earth leakage, 10 kA breaking capacity, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60HC45R100 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeClass AC
Earth-leakage trip time delayInstantaneous
Trip unit technologyThermal-magnetic
Local signalling / indicationPositive break indication
C60HC45R100 — Electrical Ratings
ParameterValue
Rated current (In)45 A at 30 °C
Rated operational voltage (Ue)50...250 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionRight
Network typeAC
Network frequency50/60 Hz
Device location in systemOutgoer
Electrical durability20000 cycles
C60HC45R100 — Identification
ParameterValue
Device short nameC60H RCBO
C60HC45R100 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminals (downstream) 10 mm² flexible Tunnel type terminals (downstream) 16 mm² rigid Tunnel type terminals (upstream) 16 mm² flexible Tunnel type terminals (upstream) 25 mm² rigid
Terminal tightening torque2 N.m
C60HC45R100 — Environmental
ParameterValue
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2
C60HC45R100 — Approvals
ParameterValue
StandardsIEC 1009-2-2

Product details

The C60HC45R100 is a C60H-series RCBO (residual current circuit breaker with overcurrent protection) from Schneider Electric, combining a 45 A thermal-magnetic MCB with 100 mA earth-leakage protection in a single 1P+N module. It snaps onto 35 mm symmetrical DIN rail and is rated for distribution outgoer circuits at 50...250 V AC, 50/60 Hz.

The 10 kA Icu breaking capacity at 50...250 V AC conforms to IEC 1009 — sufficient for most sub-distribution boards where the upstream fault level is limited. Earth-leakage sensitivity is 100 mA, Class AC (instantaneous), meaning it detects sinusoidal residual currents only; not suitable for pulsating DC or variable-frequency drive circuits that generate smooth DC fault currents. Thermal-magnetic trip technology gives both overload (thermal bimetal) and short-circuit (solenoid) protection in one unit. The 20,000-cycle electrical durability is typical for a distribution RCBO — adequate for branch circuits with infrequent switching, not for motor-starting duty where higher endurance is needed.

Schneider lists the C60HC45R100 as obsolete. If a form-fit-function replacement is needed, a parametric search for a 1P+N RCBO at 45 A, C-curve, 100 mA sensitivity, 10 kA breaking capacity, and DIN-rail mount will identify candidates; verify terminal capacity and neutral position (right) before substituting.

The 1P+N module occupies two 9 mm pitches, so it fits a standard 18 mm width. Positive-break indication on the toggle gives visual confirmation of contact separation.

Frequently asked questions

Where can I buy C60HC45R100 and how do I get a price?

The C60HC45R100 is sourced to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What standards does the C60HC45R100 comply with?

The C60HC45R100 is designed to IEC 1009-2-2 (the RCBO product standard) and its limitation class 3 conforms to EN 60898.

What is the C60HC45R100's curve code and what does it mean?

The C curve on this RCBO means the magnetic trip operates between 5 and 10 times the rated current (5...10 × In), suited for circuits with moderate inrush like lighting or small motors.

MPN
C60HC45R100