Schneider Electric C60HC6R100 — Residual Current Breakers (RCCB/RCBO)

C60HC6R100 C60H RCBO, 6 A, C-Curve, 10 kA, Obsolete

MPNC60HC6R100
Obsolete

Schneider Electric C60H series RCBO, 1 pole + neutral, 6 A rated current, C-curve, 100 mA earth leakage, 10 kA breaking capacity, obsolete status.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60HC6R100 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeClass AC
Earth-leakage trip time delayInstantaneous
Trip unit technologyThermal-magnetic
Local signalling / indicationPositive break indication
C60HC6R100 — Electrical Ratings
ParameterValue
Rated current (In)6 A at 30 °C
Rated operational voltage (Ue)50...250 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionRight
Network typeAC
Network frequency50/60 Hz
Device location in systemOutgoer
Electrical durability20000 cycles
C60HC6R100 — Identification
ParameterValue
Device short nameC60H RCBO
C60HC6R100 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminals (downstream) 10 mm² flexible Tunnel type terminals (downstream) 16 mm² rigid Tunnel type terminals (upstream) 16 mm² flexible Tunnel type terminals (upstream) 25 mm² rigid
Terminal tightening torque2 N.m
C60HC6R100 — Environmental
ParameterValue
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2
C60HC6R100 — Approvals
ParameterValue
StandardsIEC 1009-2-2

Product details

The C60HC6R100 is a C60H series residual current circuit breaker with overcurrent protection (RCBO), 1 pole + neutral, rated 6 A at 30 °C with a C-curve magnetic trip of 5...10 x In. It carries a 10 kA breaking capacity at 50...250 V AC 50/60 Hz per IEC 1009, and 100 mA earth leakage protection, Class AC, instantaneous. This is the outgoer protection for a distribution board — one module wide on 35 mm DIN rail, toggle actuated, with positive break indication on the handle.

This part is marked obsolete by the manufacturer.

The C-curve (5...10 x In) means magnetic trip between 30 A and 60 A — typical for inductive loads like small contactor coils or lighting ballasts where inrush exceeds a B-curve threshold. The 100 mA earth leakage sensitivity is Class AC (sinusoidal AC only), instantaneous — no time delay, so it trips on first fault. That sensitivity is common for general socket-outlet protection where 30 mA is too sensitive for the circuit leakage. Terminal capacity: 25 mm² rigid upstream, 16 mm² flexible downstream — enough for a 6 A circuit with some headroom for voltage drop.

Integration Notes

Mounts on 35 mm symmetrical DIN rail — one module width (roughly 9 mm pitch, 2 pitches total). Neutral is on the right. Tunnel terminals: torque to 2 N.m. Operating altitude limited to 2000 m; relative humidity 95 % at 55 °C, so it handles damp enclosure environments but not outdoor direct exposure.

Frequently asked questions

Where can I buy C60HC6R100?

This obsolete part is sourced through independent distribution channels. Submit an RFQ for current availability and pricing; it is quoted to order, not held as live stock.

What is the C60HC6R100's breaking capacity?

It is rated 10 kA Icu at 50...250 V AC 50/60 Hz conforming to IEC 1009.

What standards does C60HC6R100 comply with?

It complies with IEC 1009-2-2 and is limitation class 3 conforming to EN 60898.