Skip to main content
Schneider Electric C60HC6RA30 — Residual Current Breakers (RCCB/RCBO)

C60HC6RA30 C60H RCBO, 1P+N, 6A, C Curve, 30mA, Obsolete

MPNC60HC6RA30
Obsolete

Schneider Electric C60H RCBO, 1 pole + N, 6 A, C curve, 30 mA earth leakage, 10 kA breaking capacity, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60HC6RA30 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeClass A
Earth-leakage trip time delayInstantaneous
Trip unit technologyThermal-magnetic
Local signalling / indicationPositive break indication
C60HC6RA30 — Electrical Ratings
ParameterValue
Rated current (In)6 A at 30 °C
Rated operational voltage (Ue)50...250 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionRight
Network typeAC
Network frequency50/60 Hz
Device location in systemOutgoer
Electrical durability20000 cycles
C60HC6RA30 — Identification
ParameterValue
Device short nameC60H RCBO
C60HC6RA30 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminals (downstream) 10 mm² flexible Tunnel type terminals (downstream) 16 mm² rigid Tunnel type terminals (upstream) 16 mm² flexible Tunnel type terminals (upstream) 25 mm² rigid
Terminal tightening torque2 N.m
C60HC6RA30 — Environmental
ParameterValue
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2
C60HC6RA30 — Approvals
ParameterValue
StandardsIEC 1009-2-2

Product details

The C60HC6RA30 is a C60H-series RCBO (residual current circuit breaker with overcurrent protection) from Schneider Electric, combining a 1P+N thermal-magnetic miniature circuit breaker with 30 mA earth-leakage protection in a single 35 mm DIN-rail module.

Schneider Electric lists the C60HC6RA30 as obsolete.

The C curve (5–10 × In magnetic trip) suits loads with moderate inrush, such as small motor starters, lighting banks, or control transformers — the breaker holds through brief startup peaks but trips fast on hard shorts. Class A earth-leakage protection (30 mA instantaneous) catches line-to-ground faults on personnel-protection circuits. Terminal capacity: up to 25 mm² rigid upstream, 16 mm² flexible downstream — enough for 6 A feeder wiring. The positive-break indication gives a visible air gap on the toggle when tripped, which helps lockout/tagout verification.

Frequently asked questions

Where can I buy C60HC6RA30 and how do I get a price?

The C60HC6RA30 is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is C60HC6RA30's listed standards (IEC 1009-2-2) on this component line?

The C60HC6RA30 is designed and tested to IEC 1009-2-2, with a limitation class of 3 conforming to EN 60898.

What is C60HC6RA30's listed curve code (C) on this component line?

The C60HC6RA30 uses a C curve, with magnetic tripping between 5 and 10 times the rated current (In).

MPN
C60HC6RA30