Schneider Electric C60WM — Miniature Circuit Breakers (MCB)

Schneider Electric C60WM MicroLogic 6.0 Control Unit, 630-16

MPNC60WM
Active

Schneider Electric ComPacT NS630b-1600, MicroLogic 6.0 control unit, electronic trip, 630-1600 A at 50 °C, IEC 60947-4-2.

$4,209.84Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

C60WM — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeControl unit
Device applicationDistribution

Ratings

C60WM — Ratings
ParameterValue
Network type (AC/DC)AC
Network frequency50/60 Hz

Protection

C60WM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout

Mechanical

C60WM — Mechanical
ParameterValue
Local signalling/indication3 LEDs (red) for electrical fault 1 LED (red) for internal error 1 LED (yellow) for overload

Environmental

C60WM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C

Approvals

C60WM — Approvals
ParameterValue
StandardsIEC 60947-4-2

Specifications

C60WM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsSelective + earth-fault protection

Product details

MicroLogic 6.0 control unit for ComPacT NS630b-1600

The Schneider Electric C60WM is a MicroLogic 6.0 electronic control unit for the ComPacT NS630b-1600 new generation withdrawable circuit breakers. It provides selective (S) and earth-fault (G) protection on top of the standard long-time (L) and instantaneous (I) functions — the LSI+G protection suite. Rated for trip unit currents from 630 A up to 1600 A at 50 °C, this is the brain that decides when the breaker opens and how fast.

What the protection settings mean on the line

The long-time pickup (Ir) adjusts from 0.4 to 1.0 x In across nine settings, with a thermal memory that holds the heat profile for 20 minutes — critical for motor starts where the second start sees a warmer conductor. Short-time pickup (Isd) spans 1.5 to 10 x Ir, also nine settings, with delay adjustable 0 to 0.4 s (I²t on or off). Instantaneous pickup (Ii) goes 2 to 15 x In, and can be switched Off entirely for selective coordination downstream. Ground-fault pickup (Ig) adjusts from 0.2 to 1.0 x In (for 400 A < In < 1250 A), with delay matching the short-time range. All of this means the unit can be dialed in for a specific feeder's coordination study — not just a fixed curve.

This control unit is designed for the withdrawable version of the ComPacT NS630b-1600 frame. That means the breaker chassis stays wired to the bus; the cradle-mounted unit slides in and out for testing or swap without disturbing the main power connections. The protected poles config is 4t, 3t, or 3t + N/2 — covers three- and four-pole arrangements. Local signaling uses three red LEDs for electrical faults, one red for internal error, one yellow for overload. No zone-selective interlocking (ZSI) on this variant.

Frequently asked questions

What is C60WM's listed range and standards?

The C60WM belongs to the ComPacT NS630b-1600 new generation range and is designed to IEC 60947-4-2, the standard for contactors and motor-starters with integral overload protection.

What protection functions does the MicroLogic 6.0 control unit provide?

The MicroLogic 6.0 provides long-time (L) overload, short-time (S) selective short-circuit, instantaneous (I) short-circuit, and ground-fault (G) earth-leakage protection — the LSI+G suite. All pickup and delay settings are field-adjustable.

Where can I buy the C60WM and what is the lead time?

The C60WM is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

MPN
C60WM