Skip to main content
Schneider Electric CAD326BLS207 — Contactors

CAD326BLS207 TeSys D Control Relay, 3 NO + 2 NC, 24 V DC

MPNCAD326BLS207
Active

Schneider Electric TeSys D control relay, CAD326BLS207, 3 NO + 2 NC, 690 V rated, 24 V DC low-consumption coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

CAD326BLS207 — Identification
ParameterValue
Product / component typeControl relay
Series / rangeTeSys
ApplicationControl circuit
CAD326BLS207 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)10 MOhm
Utilisation categoryDC-13 AC-14 AC-15
CAD326BLS207 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude0...3000 m
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV0 conforming to UL 94
CAD326BLS207 — Approvals
ParameterValue
StandardsEN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
CAD326BLS207 — Mechanical
ParameterValue
Width45 mm
Height77 mm
Depth93 mm

Product details

The CAD326BLS207 is a TeSys D control relay from Schneider Electric, built for switching control circuits in motor starter and automation panels. It gives you 3 normally-open and 2 normally-closed contacts — the 3 NO handle the main pilot-duty loads, the 2 NC are your feedback or interlock paths. Rated utilisation categories AC-15 and AC-14 cover solenoid and electromagnetic loads common in contactor coils and small valve actuators; DC-13 covers DC solenoids with similar inductive kick. That means this relay is sized for the control transformer secondary, not the motor power legs — it lives on the 24 V DC bus or 110/230 V AC pilot circuit. The 24 V DC low-consumption coil draws less from your power supply than a standard AC coil, which matters when you're stacking several relays in a panel and watching the 24 V bus budget.

Dimensions are 45 mm wide, 77 mm tall, 93 mm deep — the 45 mm width is a standard 2.5-module DIN-rail footprint, so it clips onto the rail alongside breakers and contactors without wasting space. Fire resistance to 850 °C (IEC 60695-2-1) and V0 flame retardance (UL 94) mean the relay won't sustain a flame in a fault scenario — important for railway and building infrastructure compliance. The TH protective treatment per IEC 60068 adds resistance to tropical humidity, so it's suited for coastal or high-moisture plant environments.

Frequently asked questions

What compliance documentation is available for CAD326BLS207?

The relay carries UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1 and 60947-5-1 certifications, plus EN 45545 R22 HL3 for railway fire safety. RoHS and REACH compliance is standard for the TeSys D range but not explicitly listed in this part's evidence.

What is the depth of CAD326BLS207?

93 mm. That's the depth behind the panel face, so verify your enclosure depth if you're replacing an existing relay with a deeper footprint.

What is the range for CAD326BLS207?

TeSys D — Schneider Electric's modular contactor and control relay family, widely used in motor control centres and industrial panels.