Skip to main content
Schneider Electric CAD326SDS207 — Contactors

TeSys CAD326SDS207 control relay, 3NO+2NC, 72 V DC, obsolete

MPNCAD326SDS207
Obsolete

Schneider Electric TeSys CAD control relay, 3 NO + 2 NC, 690 V, 72 V DC standard coil, IP20 front face, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

CAD326SDS207 — Identification
ParameterValue
Product / component typeControl relay
Series / rangeTeSys
ApplicationControl circuit
CAD326SDS207 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)10 MOhm
Utilisation categoryAC-15 DC-13 AC-14
CAD326SDS207 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude0...3000 m
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV0 conforming to UL 94
CAD326SDS207 — Approvals
ParameterValue
StandardsEN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
CAD326SDS207 — Mechanical
ParameterValue
Width45 mm
Height77 mm
Depth93 mm

Product details

The 3 NO + 2 NC contact arrangement gives you three normally-open and two normally-closed poles, which is a common pattern for control circuits that need to switch multiple loads or interlocks simultaneously. The utilisation categories — AC-15, AC-14, and DC-13 — tell you it is rated for switching electromagnetic loads (contactors, relays, solenoids) at currents well below the contactor's own main pole rating. AC-15 covers inductive loads above 72 VA; AC-14 covers electromagnetic loads below 72 VA; DC-13 covers DC solenoids and relays. This is a control-circuit relay, not a power-switching contactor — it lives in the panel wiring, not the motor circuit.

Frequently asked questions

What is the closest replacement for CAD326SDS207?

No official successor order code is listed for this part. A replacement would need to match the 3 NO + 2 NC contact configuration, 72 V DC coil, and TeSys D footprint. A current TeSys D control relay with those parameters would be the starting point for a cross-reference, but pin compatibility and terminal layout should be verified against the original panel wiring.

What compliance documentation is available for CAD326SDS207?

The relay carries certifications to EN 45545 R22 HL3 (railway fire safety), EN/IEC 60947-4-1 and 60947-5-1 (control circuit devices), UL 60947-4-1, and CSA C22.2 No 60947-4-1. It also meets IEC 60695-2-1 for glow-wire resistance at 850 °C and UL 94 V0 for flame retardance. Protective treatment is TH per IEC 60068 for tropical environments.

MPN