CAD32AEL — Identification
ParameterValue
Product / component typeControl relay
Series / rangeTeSys
ApplicationControl circuit
CAD32AEL — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)10 MOhm
Utilisation categoryAC-15 AC-14 DC-13
CAD32AEL — Environmental
ParameterValue
IP degree of protectionIP2X front face conforming to VDE 0106
Operating altitude0...3000 m
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTH conforming to IEC 60068
CAD32AEL — Approvals
ParameterValue
StandardsEN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1
CAD32AEL — Mechanical
ParameterValue
Width45 mm
Height107 mm
Depth93 mm
CAD32AEL — Other specifications
ParameterValue
Device short nameCAD
Pole contact composition3 NO + 2 NC
Ambient air temperature for storage-60...80 °C
Ambient air temperature for operation-40...60 °C 60...70 °C with derating

Product details

The Schneider Electric TeSys CAD32AEL is a Deca-series control relay with a 3 NO + 2 NC pole configuration, rated for operational voltages up to 690 V and fitted with a 48 V DC low-consumption coil. It uses snap-in terminals for fast panel wiring.

The 3 NO + 2 NC contact arrangement gives you three normally-open and two normally-closed auxiliary contacts — enough to handle a start/stop interlock plus a status feedback pair in a motor starter or valve control circuit. The 48 V DC coil is a low-consumption variant, meaning it draws less control power than a standard DC coil, which matters when the 24 VDC supply is shared across multiple relays in a panel. Utilisation categories AC-15, AC-14, and DC-13 cover solenoid-valve and contactor-coil switching (AC-15), electromagnetic loads at lower currents (AC-14), and DC inductive loads like brake coils or DC contactors (DC-13). The relay is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1 — so it is accepted in European, North American, Chinese, and Japanese panels without extra paperwork. Mechanical robustness is specified: the relay withstands 10 Gn shocks when open and 15 Gn when closed, plus vibration of 2 Gn (open) and 4 Gn (closed) across 5–300 Hz. That is enough for most industrial machinery but worth checking if the panel is mounted on a high-vibration press or mobile equipment.

The IP2X front-face protection (per VDE 0106) means accidental finger contact with live terminals is prevented — standard for open-panel installations.

Frequently asked questions

What is CAD32AEL's listed depth?

93 mm.

What is CAD32AEL's listed range?

TeSys (specifically the TeSys Deca series).

What compliance documentation does CAD32AEL carry?

It is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. Protective treatment TH conforming to IEC 60068 is also specified.

MPN
CAD32AEL