CAD32AS7 — Identification
ParameterValue
Product / component typeControl relay
Series / rangeTeSys
ApplicationControl circuit
CAD32AS7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)10 MOhm
Utilisation categoryAC-15 AC-14 DC-13
CAD32AS7 — Environmental
ParameterValue
IP degree of protectionIP2X front face conforming to VDE 0106
Operating altitude0...3000 m
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTH conforming to IEC 60068
CAD32AS7 — Approvals
ParameterValue
StandardsEN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1
CAD32AS7 — Mechanical
ParameterValue
Width45 mm
Height107 mm
Depth93 mm
CAD32AS7 — Other specifications
ParameterValue
Device short nameCAD
Pole contact composition3 NO + 2 NC
Ambient air temperature for storage-60...80 °C
Ambient air temperature for operation-40...60 °C 60...70 °C with derating

Product details

The CAD32AS7 is a TeSys Deca control relay from Schneider Electric's TeSys range, configured with 3 normally-open and 2 normally-closed contacts. It's designed for control-circuit switching in industrial panels, rated for operational voltages up to 690 V and carrying utilisation categories AC-15, AC-14, and DC-13 — meaning it handles solenoid and electromagnetic loads in AC control circuits, and DC inductive loads like contactor coils. The 500 V AC standard coil is built into the snap-in terminal base.

The DC-13 rating covers DC inductive loads, which is relevant when the relay is switching DC contactor coils or brake solenoids in a panel. The 3NO+2NC contact arrangement gives you three independent make contacts for pilot devices or PLC inputs, plus two break contacts for safety interlocks or status feedback. Mechanical robustness is specified: the relay withstands 10 Gn shocks for 11 ms in the open position and 15 Gn when closed, with vibration resistance of 2 Gn (open) and 4 Gn (closed) across 5–300 Hz. That's enough for installation on machinery with moderate vibration — conveyors, pumps, compressors — without nuisance dropout. The IP2X front-face protection means finger-safe to VDE 0106, which is standard for enclosed panel mounting. Operating temperature spans -40 to 60 °C, with derating required above 60 °C up to 70 °C. Storage range is -60 to 80 °C. Altitude rating goes to 3000 m without derating. The TH protective treatment per IEC 60068 means the relay is treated against tropical humidity — suitable for non-condensing environments in most industrial settings.

The snap-in terminals accept the coil and contact wiring; no separate base is needed. Mount it alongside contactors in a motor control centre or as an interposing relay between a PLC output card and higher-current loads.

Frequently asked questions

What utilisation categories does CAD32AS7 carry?

It is rated for AC-15, AC-14, and DC-13. AC-15 covers switching electromagnetic loads (contactors, solenoids) in AC control circuits; DC-13 covers DC inductive loads like DC contactor coils.

What compliance standards does CAD32AS7 meet?

It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. The TH protective treatment conforms to IEC 60068 for tropical environments.

What is the contact configuration?

3 normally-open and 2 normally-closed poles. That gives three make contacts for pilot/control signals and two break contacts for safety or status feedback.

What are the mounting dimensions?

Width 45 mm, height 107 mm, depth 93 mm. It snaps onto standard DIN rail. The IP2X front face is finger-safe per VDE 0106.