CAD50Q7 Schneider TeSys D control relay 5 NO 380 V AC

MPNCAD50Q7
Obsolete

Schneider TeSys D control relay, CAD50Q7, 5 NO contacts, 380 V AC standard coil, EN/IEC 60947-5-1, UL, CSA, CCC, IP2X front face, 45.72 mm width.

$50.58 – $67.77Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

CAD50Q7 specifications
ParameterValue
Product or component typeControl relay
[Ue] rated operational voltage10 MOhm
Pole contact composition5 NO
Utilisation categoryAC-15 AC-14 DC-13
IP degree of protectionIP2X front face VDE 0106
Operating altitude0...9842.52 ft (0...3000 m)
Depth3.3 in (84 mm)
Width1.8 in (45 mm)
Height3.03 in (77 mm)
StandardsEN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1
RangeTeSys TeSys Deca
CategoryUS10I1222371
Device short nameCAD
Protective treatmentTH IEC 60068
Contactor applicationControl circuit
Mechanical robustnessShocks control relay open10 Gn for 11 ms IEC 60068-2-27 Shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 Vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 Vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating

Product details

Overview

The CAD50Q7 is a Schneider TeSys D control relay, order code CAD50Q7, with 5 normally-open contacts rated for control circuits up to 690 V. The coil is wound for 380 V AC standard supply. It carries certifications under EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, and JIS C8201-5-1, with an IP2X front face per VDE 0106.

The five NO poles switch control loads in AC-15, AC-14, and DC-13 utilization categories — covering solenoid valves, contactor coils, and resistive loads typical in machine control panels. The 380 V AC coil draws from standard line voltage without a step-down transformer.

Applications

This relay mounts inside motor control centres and panel boards to interlock contactors, signal PLC inputs, or extend auxiliary contact capacity on larger TeSys starters. The 5 NO arrangement suits circuits that need multiple isolated make contacts from a single coil command.

MPN
CAD50Q7