Schneider Electric CV1BJ2J0ZM522 — Contactors

TeSys CV1BJ2J0ZM522 Contactor, 470A AC-3, 2P, 220VAC Coil

MPNCV1BJ2J0ZM522
Active

Schneider Electric TeSys B, contactor, 2 poles, AC-3 690 V 470 A, coil 220 V AC 50 Hz, 2 NO + 2 NC auxiliary contacts.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

CV1BJ2J0ZM522 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive circuits, heating, lighting Motor

Ratings & Performance

CV1BJ2J0ZM522 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
Utilisation categoryAC-1 AC-3

Contacts & Poles

CV1BJ2J0ZM522 — Contacts & Poles
ParameterValue
Pole configuration2P

Other specifications

CV1BJ2J0ZM522 — Other specifications
ParameterValue
Device short nameCV1BJ
Control circuit typeAC
Pole contact composition2 NO
Coil voltage220 V AC 50 Hz
Auxiliary contact composition2 NO + 2 NC
[Ie] rated operational current470 A AC for power circuit
Current rating code of contactorBJ

Product details

The CV1BJ2J0ZM522 is a TeSys B contactor with two main poles, each normally open, rated for 470 A in AC-3 duty at 690 V AC. AC-3 means it is designed for switching squirrel-cage motors — making and breaking motor starting currents. The same contactor also carries an AC-1 rating for resistive loads like heating or lighting circuits, where the switching current is essentially the load current with no motor inrush. The control coil is rated 220 V AC at 50 Hz. The contactor includes two normally open and two normally closed auxiliary contacts for feedback or interlocking in the control circuit.

The headline number is 470 A at 690 V AC in AC-3. That is the motor-switching rating — the current the main poles can make and break under motor start conditions. The 2-pole configuration limits it to single-phase or DC switching applications. The 220 V AC coil means it integrates into a control transformer secondary or existing 230 V control bus. The auxiliary contact complement (2 NO + 2 NC) is generous for a contactor of this size — enough for a holding circuit plus two status feedbacks without an add-on block.

The 2-pole body is narrower than a 3-pole equivalent, saving rail space in panels where only single-phase or DC motor switching is needed. The auxiliary contacts are built-in, so no separate side-mount block is required for basic feedback. The main power terminals accept cable lugs sized for 470 A — expect M10 or M12 studs, verify against the product datasheet for lug dimensions.

Frequently asked questions

What control voltage does the coil require?

220 V AC at 50 Hz.

How many auxiliary contacts does it have?

Two normally open and two normally closed auxiliary contacts, built into the contactor.

MPN
CV1BJ2J0ZM522