Schneider Electric CV1BJ3J0ZM532 — Contactors

TeSys CV1BJ3J0ZM532 Contactor, 470A AC-3, 220V AC Coil

MPNCV1BJ3J0ZM532
Active

Schneider Electric TeSys B contactor, CV1BJ3J0ZM532, 3-pole, 470 A AC-3 at 690 V, 220 V AC 50 Hz coil, 3 NO + 2 NC auxiliary contacts.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

CV1BJ3J0ZM532 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor Resistive circuits, heating, lighting

Ratings & Performance

CV1BJ3J0ZM532 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
Utilisation categoryAC-1 AC-3

Contacts & Poles

CV1BJ3J0ZM532 — Contacts & Poles
ParameterValue
Pole configuration3P

Other specifications

CV1BJ3J0ZM532 — Other specifications
ParameterValue
Device short nameCV1BJ
Control circuit typeAC
Pole contact composition3 NO
Coil voltage220 V AC 50 Hz
Auxiliary contact composition3 NO + 2 NC
[Ie] rated operational current470 A AC for power circuit
Current rating code of contactorBJ

Product details

The 220 V AC 50 Hz coil pulls in cleanly on a standard control transformer; verify the control circuit supplies the full rated voltage at the coil terminals, not the bus side of a long run. The 3 NO main poles and the built-in 3 NO + 2 NC auxiliary contacts cover most motor starter schemes without an add-on block. The AC-1 rating (resistive loads like heating or lighting) is higher than the AC-3 motor rating, so the limiting factor for motor duty is the 470 A AC-3 figure.

The TeSys B frame accepts screw-clamp or spring-cage power terminations; verify the lug kit matches your cable cross-section before terminating. The coil draws inrush current at pickup — size the control transformer for the peak, not the sealed VA. Auxiliary contacts share the same arc-suppression guidelines as the main poles; a snubber across the coil extends life on frequent cycling.

Frequently asked questions

What is the rated operational current for motor duty?

The AC-3 rated operational current is 470 A at 690 V AC. This is the figure to use for sizing the contactor for three-phase induction motor loads.

What auxiliary contacts are built in?

The contactor includes 3 normally open and 2 normally closed auxiliary contacts as standard, which is enough for most interlocking and status feedback circuits without an additional block.

What coil voltage does this contactor require?

The control circuit voltage is 220 V AC at 50 Hz. Ensure the control transformer and wiring deliver this at the coil terminals during pickup.