Skip to main content
Schneider Electric CV1BK3K0ZM511 — Contactors

TeSys CV1BK3K0ZM511 Contactor, 630A AC-3, 220V AC Coil

MPNCV1BK3K0ZM511
Active

Schneider Electric TeSys B, 3-pole contactor, 630 A AC-3, 690 V AC, 220 V AC 50 Hz coil, 1 NO + 1 NC auxiliary.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

CV1BK3K0ZM511 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor Resistive circuits, heating, lighting

Ratings & Performance

CV1BK3K0ZM511 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
Utilisation categoryAC-1 AC-3

Contacts & Poles

CV1BK3K0ZM511 — Contacts & Poles
ParameterValue
Pole configuration3P

Other specifications

CV1BK3K0ZM511 — Other specifications
ParameterValue
Device short nameCV1BK
Control circuit typeAC
Pole contact composition3 NO
Coil voltage220 V AC 50 Hz
Auxiliary contact composition1 NO + 1 NC
[Ie] rated operational current630 A AC for power circuit
Current rating code of contactorBK

Product details

The CV1BK3K0ZM511 is a TeSys B contactor from Schneider Electric's TeSys range, a 3-pole unit rated for 630 A in AC-3 duty at 690 V AC. That AC-3 category means it's designed for starting and stopping squirrel-cage induction motors under load — the standard use case for motor control in industrial panels. The 630 A AC-3 rating is the headline figure for motor switching. For resistive or heating loads (AC-1 category), the contactor can carry higher current, but the 630 A AC-3 number is what governs motor sizing. The coil pulls 220 V AC at 50 Hz, so it's a direct fit for European-standard control circuits.

The 3 NO main poles handle the motor power circuit; the built-in 1 NO + 1 NC auxiliary contact block provides feedback or interlocking without an add-on module. For a 630 A motor branch, you'll want to coordinate the upstream short-circuit protection (MCCB or fuse) to match the contactor's making and breaking capacity.

Frequently asked questions

What utilisation categories does this contactor support?

It is rated for AC-1 (resistive loads, heating, lighting) and AC-3 (squirrel-cage motor starting/stopping). The 630 A figure applies to AC-3 motor duty at 690 V AC.

What is the control voltage and frequency?

The coil is rated for 220 V AC at 50 Hz. That is a standard European control voltage — verify your panel's control transformer matches before wiring.

MPN
CV1BK3K0ZM511