Skip to main content
Schneider Electric CV1BL2L0ZM522 — Contactors

TeSys CV1BL2L0ZM522 Contactor, 2P, 1000A AC-3, 220VAC Coil

MPNCV1BL2L0ZM522
Active

Schneider Electric TeSys B, CV1BL2L0ZM522, 2-pole contactor, 1000 A AC-3 at 690 V, 220 V AC 50 Hz coil.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

CV1BL2L0ZM522 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor Resistive circuits, heating, lighting

Ratings & Performance

CV1BL2L0ZM522 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
Utilisation categoryAC-1 AC-3

Contacts & Poles

CV1BL2L0ZM522 — Contacts & Poles
ParameterValue
Pole configuration2P

Other specifications

CV1BL2L0ZM522 — Other specifications
ParameterValue
Device short nameCV1BL
Control circuit typeAC
Pole contact composition2 NO
Coil voltage220 V AC 50 Hz
Auxiliary contact composition2 NO + 2 NC
[Ie] rated operational current1000 A AC for power circuit
Current rating code of contactorBL

Product details

The Schneider Electric TeSys B CV1BL2L0ZM522 is a 2-pole contactor rated for 1000 A in AC-3 duty at 690 V, with a 220 V AC 50 Hz coil. That AC-3 rating means it's built for switching squirrel-cage motors — making and breaking currents up to that full-load figure, not just carrying them. The AC-1 rating covers resistive loads like heating and lighting, where the switching arc is less aggressive.

This contactor mounts on a panel plate or DIN rail, switching the main power feed to a motor or resistive heater bank. The 2 NO main poles switch both lines on a single-phase or DC circuit, or two phases of a three-phase system. The 2 NO + 2 NC auxiliary contacts provide feedback for a PLC or holding circuit without a separate block.

Frequently asked questions

What is the rated operational current for this contactor?

It is rated 1000 A for the power circuit under AC-3 utilization category at 690 V. That is the motor-switching current, not just the carry current.

What coil voltage does this contactor use?

The control circuit is 220 V AC at 50 Hz. Make sure your control transformer or supply matches that voltage and frequency.

What auxiliary contacts does it have?

It comes with 2 normally-open and 2 normally-closed auxiliary contacts built in. That covers most feedback and interlock needs without an add-on block.

MPN
CV1BL2L0ZM522