Skip to main content
Schneider Electric CV1BL3L0ZM711 — Contactors

TeSys CV1BL3L0ZM711 Contactor, 375 kW AC-3, 700 A, 220 VAC C

MPNCV1BL3L0ZM711
Active

Schneider Electric TeSys B series, CV1BL3L0ZM711, 3-pole contactor, AC-3 690 V 1000 A, coil 220 V AC.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

CV1BL3L0ZM711 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive circuits, heating, lighting Motor

Ratings & Performance

CV1BL3L0ZM711 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
Utilisation categoryAC-3 AC-1

Contacts & Poles

CV1BL3L0ZM711 — Contacts & Poles
ParameterValue
Pole configuration3P

Product details

What this contactor is rated for

The CV1BL3L0ZM711 is a 3-pole contactor from the TeSys B family, rated for motor switching at 375 kW on a 400 V AC 50/60 Hz supply under AC-3 duty. That AC-3 utilisation category covers starting and stopping squirrel-cage motors — the load current during acceleration and the break current at full speed. For resistive loads (AC-1), the rated operational current is 1000 A; for motor loads (AC-3), it's 700 A.

That's a standard industrial control voltage in many regions — the contactor picks up reliably at that level. The auxiliary contact composition is 1 NO + 1 NC, which gives you one feedback or interlock circuit and one status signal without needing an add-on block for basic applications.

Connections and mounting

Terminals are bolted connection — expect to torque power and control wires to the manufacturer's specification. The contactor is designed for panel mounting; given the 700 A continuous rating, busbar or cable sizing and thermal management in the enclosure need attention. The 3 NO main poles handle the power circuit; no NC main pole is present.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational voltage is 690 V AC. For AC-3 motor duty, the rated operational current is 700 A, supporting a motor power of 375 kW at 400 V AC 50/60 Hz. For AC-1 resistive duty, the rated current is 1000 A. The coil is 220 V AC 50/60 Hz.

What utilisation categories does this contactor cover?

It is rated for AC-3 (squirrel-cage motor starting and stopping) and AC-1 (resistive loads such as heating and lighting). The application list includes resistive circuits, heating, lighting, and motor loads.

What auxiliary contacts are included?

The contactor ships with 1 normally open and 1 normally closed auxiliary contact. This provides one feedback or interlock signal and one status indication without an additional block.

MPN
CV1BL3L0ZM711