Skip to main content
Schneider Electric ELNME4U22AAA

Schneider Electric ELNME4U22AAA

MPNELNME4U22AAA
Active

MX eco 4V2.2 - variable speed drive - 2.2kW - 400V - 3PH - EMC - IP20

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ELNME4U22AAA key specifications
ParameterValue
Connector type1 RJ45 (on terminal) for Modbus Male SUB-D 9 on RJ45 for CANopen
Range of productMX eco
Product or component typeVariable speed drive
Supply voltage limits323...528 V
Supply voltage380...480 V - 15...10 %
Line current8.2 A for 400 V, 3 phases, 2.2 kW (without choke) 7.1 A for 480 V, 3 phases, 3 hp (without choke)
Continuous output current5.8 A at 4 kHz, 400 V3 phases 5.8 A at 4 kHz, 460 V3 phases
Maximum transient current7 A for 60 s 3 phases
Apparent power4 kVA for 400 V3 phases / 2.2 kW 4.6 kVA for 460 V3 phases / 3 hp
Motor power2.2 kW 3 phases for 380...480 V
Supply frequency50...60 Hz +/-5 %
Switching frequency2...16 kHz adjustable 4...16 kHz with derating factor

All specifications

ELNME4U22AAA additional specifications
ParameterValue
Frequency resolutionDisplay unit: 0.1 Hz Analog input: 0.01/50 Hz
Network frequency limits47.5...63 Hz
Nominal switching frequency4 kHz
Speed drive output frequency0...300 Hz
Network number of phases3 phases
IP degree of protectionIP20 top without protective cover conforming to EN/IEC 61800-5-1 and EN/IEC 60529 IP21 bottom, sideways and front conforming to EN/IEC 61800-5-1 and EN/IEC 60529 IP41 top conforming to EN/IEC 61800-5-1 and EN/IEC 60529
Physical interface2-wire RS 485 for Modbus
Communication port protocolCANopen Modbus
EMC filterIntegrated
Pollution degree2 conforming to EN/IEC 61800-5-1
Shock resistance15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Operating altitude1000...3000 m with current derating 1 % per 100 m
Vibration resistance1.5 mm peak to peak (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-6
Depth175 mm
Width130 mm
Height230 mm
StandardsEN/IEC 61800-5-1 EN 50178 EN/IEC 60721-3-3 class 3C1 and 3S2 EN/IEC 61800-5-2 EN/IEC 61800-3 environments 1 and 2 category C1, C2, C3
Data format8 bits, odd even or no configurable parity for Modbus on terminal 8 bits, 1 stop, even parity for Modbus on front face
Noise level55 dB conforming to 86/188/EEC
Option cardCommunication card for Profibus DP Basic I/O extension card Extended I/O extension card
Assembly styleBuilt-in unit with forced cooling
Braking torque30 % without braking resistor 1 mOhm 500 V DC for 1 minute to earth
Speed accuracyV/f mode: slip frequency without speed feedback VC without feedback: 0.3 x slip frequency
Torque accuracy+/- 15 % in open-loop mode, without speed feedback
Method of accessSlave CANopen
Device short nameMX eco 4V2.2
Transmission rate24...38400 bauds for Modbus on terminal 9600 bps, 19200 bps for Modbus on front face 34 kbauds...1 Mbaud for CANopen
Operating positionVertical +/- 10 degree
Transmission frameRTU for Modbus
Number of addresses1...247 for Modbus 1...127 for CANopen
Product destinationSynchronous motors Asynchronous motors
Prospective line isc5 kA 3 phases without choke 35 kA 3 phases with DCL-choke 100 kA 3 phases with line reactor
Transient overtorque120 % of nominal motor torque for 60 s 135 % of nominal motor torque for 2 s
Product specific applicationPumping and ventilation machine
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Ambient air temperature for storage-25...70 °C
Ambient air temperature for operation-10...50 °Cwithout derating 50...60 °Cwith current derating of 2 % per °C
MPN
ELNME4U22AAA