Schneider Electric EZC100H3035 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZC100H3035 EasyPact EZC100H 3P 35A Circu

MPNEZC100H3035
Active

Schneider Electric EasyPact EZC100H, 3-pole, 35 A thermal-magnetic MCCB, TM-D trip unit, 10–100 kA Icu across voltage range, IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZC100H3035 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZC100H3035 — Mechanical
ParameterValue
Height130 mm
Width75 mm
Depth60 mm
EZC100H3035 — Electrical
ParameterValue
[In] rated current35 A at 40 °C
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
EZC100H3035 — Specifications
ParameterValue
Poles description3P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZC100H
StandardsEN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2

Product details

The Schneider Electric EZC100H3035 is a 3-pole EasyPact EZC100H circuit breaker with a TM-D thermal-magnetic trip unit rated 35 A at 50 °C. The 35 A In is set at 40 °C; the 50 °C derating is already baked into the trip unit marking — no further reduction needed at that temperature. The H breaking capacity code delivers 10 kA Icu at 550 V AC, 30 kA at 400 V AC, 50 kA at 240 V AC, and 100 kA at 110–130 V AC. At 125 V DC single-pole it holds 10 kA; double-pole series connection gives 10 kA at 250 V DC. That spread means it handles high-fault commercial mains without cascading upstream — the 30 kA at 400 V covers typical European industrial supply. The 690 V rated insulation voltage (Ui) and 550 V operational voltage (Ue) AC keep it within standard 400/480 V panel buswork with margin.

Deployment context

This breaker is a fixed-mount, front-connect distribution device sized for backplate mounting in a panel or enclosure. The 75 mm width and 60 mm depth fit standard MCCB footprints on a 25 mm connection pitch. IP20 finger protection means it is safe for open-panel installation inside a locked enclosure; IK07 impact resistance handles accidental tool strikes during maintenance. The toggle control gives positive contact indication, so a quick visual confirms open/closed state without powering a status lamp.

Frequently asked questions

What is the breaking capacity of EZC100H3035 at 400 V AC?

At 380–400 V AC 50/60 Hz, the EZC100H3035 delivers 30 kA Icu per IEC 60947-2. At 415 V it holds the same 30 kA. At 440 V it drops to 20 kA.

Where can I buy EZC100H3035?

The EZC100H3035 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does EZC100H3035 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It is certified for isolation per IEC 60947-2.

What is the difference between EZC100H3035 and a standard EZC100N breaker?

The H suffix denotes a higher breaking capacity (30 kA at 400 V vs 25 kA for the N code at the same voltage). Both share the same frame, trip unit family, and 35 A TM-D rating — the H version is specified where fault current exceeds 25 kA.

MPN
EZC100H3035