Skip to main content
Schneider Electric EZC250H3160 — Circuit Breaker Accessories

Schneider Electric EZC250H3160 EasyPact EZC250H 160A 3P MCCB

MPNEZC250H3160
Active

Schneider Electric EasyPact EZC250H, 3-pole molded case circuit breaker, 160 A, TM-D thermal-magnetic trip unit, 36 kA breaking capacity at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250H3160 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H3160 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]160 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC250H3160 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating160 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H3160 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width105 mm
Height165 mm
Depth60 mm
EZC250H3160 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H3160 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2

Product details

The Schneider Electric EZC250H3160 is a 3-pole molded case circuit breaker from the EasyPact EZC250H series, rated 160 A at 40 °C with a TM-D thermal-magnetic trip unit. It provides short-circuit and overload protection for distribution applications, with a breaking capacity of 36 kA Icu at 400...415 V AC 50/60 Hz per IEC 60947-2. The H breaking capacity code means it handles higher fault currents than the standard S or N variants in the same frame, making it suitable for main or sub-feed protection where available fault current exceeds 25 kA.

The 160 A trip unit rating at 50 °C and 160 A rated current at 40 °C define the continuous load it can carry without nuisance tripping. Breaking capacity varies by voltage: 85 kA Icu at 240 V AC, 36 kA at 400 V, 25 kA at 440 V, and 10 kA at 550 V AC. On DC systems, it delivers 30 kA Icu at 125 V DC (1-pole) or 250 V DC (2-pole). The IP20 finger-safe enclosure and IK07 impact resistance protect against accidental contact and light mechanical shock during panel maintenance.

Fixed backplate mounting with front-connect terminals — both line and load connections are on the front face, so the breaker can be installed in a panel without rear-access buswork. Toggle control with positive contact indication gives a clear visual of contact state, useful during lockout/tagout.

Frequently asked questions

How do I get current pricing and availability for EZC250H3160?

Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; the response will include current stock position and a firm price for your quantity.

What is EZC250H3160's breaking capacity at 400 V?

The breaking capacity is 36 kA Icu at 400...415 V AC 50/60 Hz per IEC 60947-2. This is the H (high) breaking capacity variant of the EZC250 frame.

What compliance standards does EZC250H3160 meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, and GB/T 14048.2. It is suitable for isolation per IEC 60947-2 and rated for pollution degree 3 per IEC 60664-1.

MPN