Specifications

EZC250H4200 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZC250H4200 — Mechanical
ParameterValue
Height165 mm
Width140 mm
Depth60 mm
EZC250H4200 — Electrical
ParameterValue
[In] rated current200 A at 40 °C
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
EZC250H4200 — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZC250H
StandardsEN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2

Product details

The Schneider Electric EZC250H4200 is a 4-pole EasyPact EZC250H molded case circuit breaker with a thermal-magnetic TM-D trip unit, rated 200 A at 40 °C. It carries an 85 kA Icu breaking capacity at 220–240 V AC, dropping to 36 kA at 380–415 V and 10 kA at 550 V — the H code tells you it's the high-breaking version for distribution panels where fault currents are known to be stiff. The 200 A frame means it's sized for a main feeder or a large motor branch circuit, not a lighting panel subfeed.

At 480 V class (380–415 V) it still holds 36 kA, which covers most industrial service-entrance requirements. The thermal-magnetic TM-D trip unit gives fixed thermal and magnetic settings — no interchangeable trip plugs, so the 200 A rating is what you get. Category A utilization means it's not intended for motor starting duty under IEC 60947-2; it's a distribution breaker, not a motor circuit protector.

Fixed backplate mount — no DIN rail adapter on this frame. Connection pitch is 35 mm, which matches standard busbar spacing for a 200 A breaker. IP20 finger protection on the front, IK07 impact resistance — it's a panel interior device, not a washdown enclosure. The toggle handle gives positive contact indication (ON/OFF/TRIPPED) visible through the front cover.

Frequently asked questions

How do I get pricing and availability for EZC250H4200?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and stock levels are confirmed at quote time.

What compliance standards does EZC250H4200 meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It is suitable for isolation per IEC 60947-2.

What is the breaking capacity of EZC250H4200 at 240 V?

85 kA Icu at 220–240 V AC 50/60 Hz per IEC 60947-2. At 380–415 V it's 36 kA; at 550 V it's 10 kA.

MPN