Skip to main content
Schneider Electric EZC250N3100 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZC250N3100 EasyPact EZC250N, 100 A, 20 k

MPNEZC250N3100
Active

Schneider Electric EasyPact EZC250N, EZC250N3100, 3-pole thermal-magnetic MCCB, 100 A rated current, 20 kA Icu at 440 V AC, TM-D trip unit, fixed mount.

$129.50Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZC250N3100 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZC250N3100 — Mechanical
ParameterValue
Height165 mm
Width105 mm
Depth60 mm
EZC250N3100 — Electrical
ParameterValue
[In] rated current100 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
EZC250N3100 — Specifications
ParameterValue
Poles description3P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZC250N
StandardsEN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

The EZC250N3100 is a 3-pole EasyPact EZC250N MCCB rated 100 A at 40 °C and 100 A at 50 °C — the thermal-magnetic TM-D trip unit handles overload and short-circuit protection without an earth-leakage module. The headline breaking capacity is 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2; that means it can safely interrupt a fault up to 20 kA at that voltage without welding contacts or cascading upstream. At 240 V AC the same frame delivers 50 kA Icu, so it covers high-fault service-entrance panels on lower-voltage legs. The 690 V rated insulation voltage and 550 V max operational voltage confirm it fits 400 V distribution networks with headroom. IP20 finger-safe terminals and IK07 impact resistance suit it for general-purpose industrial panels, not washdown zones.

Designed and tested to EN/IEC 60947-2 and GB/T 14048.2, with pollution degree 3 per IEC 60664-1 — suitable for industrial environments with conductive dust or condensation.

Frequently asked questions

How do I get current pricing and availability for EZC250N3100?

Pricing and stock levels are confirmed at quote time. Submit an RFQ through this listing; the part is sourced to order through independent distribution channels.

What is the breaking capacity of EZC250N3100 at 440 V?

The EZC250N3100 is rated 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 240 V AC the same frame delivers 50 kA Icu.

What compliance documentation does Schneider provide for EZC250N3100?

The part is certified to EN/IEC 60947-2 and GB/T 14048.2, with pollution degree 3 per IEC 60664-1. It carries IEC 60947-2 isolation suitability. RoHS and REACH declarations are standard for Schneider EasyPact products; request them with your RFQ.

MPN
EZC250N3100