Skip to main content
Schneider Electric EZC250N3250 — Circuit Breaker Accessories

Schneider Electric EZC250N3250 EasyPact EZC250N, 250 A, 3P,

MPNEZC250N3250
Active

Schneider Electric EasyPact EZC250N, molded case circuit breaker, 250 A, 3 poles, TM-D thermal-magnetic trip unit, 20 kA Icu at 440 V AC, fixed mount, IP20.

$136.83Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250N3250 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250N3250 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]250 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC250N3250 — Protection & Performance
ParameterValue
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating250 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250N3250 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width105 mm
Height165 mm
Depth60 mm
EZC250N3250 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250N3250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2

Product details

The Schneider Electric EZC250N3250 is a 3-pole molded case circuit breaker from the EasyPact EZC250N series, rated 250 A at 40 °C and fitted with a TM-D thermal-magnetic trip unit. It provides short-circuit and overload protection for distribution applications per EN/IEC 60947-2. The TM-D trip unit is thermal-magnetic, meaning it uses a bimetal element for overload protection and a solenoid for short-circuit interruption. No electronic adjustment — the trip curve is fixed, which simplifies specification but limits coordination flexibility compared to an electronic Micrologic trip unit.

The EZC250N3250 carries a 20 kA Icu (ultimate breaking capacity) at 440 V AC 50/60 Hz per IEC 60947-2. At 380 V AC that rises to 25 kA Icu, and at 220–240 V AC it reaches 50 kA Icu. For DC applications, the breaker is rated 20 kA Icu at 125 V DC (1 pole) and 20 kA Icu at 250 V DC (2 poles). The 8 kA Icu at 550 V AC marks the upper voltage limit of the device — at that voltage the interrupting capability drops, so selectivity studies should use the 550 V figure if the system runs near that level.

Fixed-mount design for backplate installation. The 105 mm width and 165 mm height fit standard panel cutouts for the EasyPac EZC250N frame size.

Frequently asked questions

Where can I buy the EZC250N3250?

The EZC250N3250 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the EZC250N3250 at 440 V AC?

The EZC250N3250 has a 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380 V AC it is 25 kA Icu, and at 220–240 V AC it reaches 50 kA Icu.

What compliance documentation does Schneider provide for the EZC250N3250?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60947-1, and GB/T 14048.2. It carries an IP20 rating per IEC 60529 and an IK07 impact rating per IEC 62262. The manufacturer provides a declaration of conformity for CE marking.

MPN
EZC250N3250