Skip to main content
Schneider Electric EZC400N3300N — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZC400N3300N EasyPact EZC400N Circuit Bre

MPNEZC400N3300N
Active

Schneider Electric EasyPact EZC400N series, EZC400N3300N, 3P molded case circuit breaker, 400 A rated current, 36 kA breaking capacity at 440 V AC, TM-D thermal-magnetic trip unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZC400N3300N — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZC400N3300N — Mechanical
ParameterValue
Height255 mm
Width140 mm
Depth110 mm
EZC400N3300N — Electrical
ParameterValue
[In] rated current400 A at 40 °C
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
EZC400N3300N — Specifications
ParameterValue
Poles description3P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZC400N
StandardsJIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

The Schneider Electric EZC400N3300N is a 3-pole molded case circuit breaker from the EasyPact EZC400N series, built for distribution applications. The breaking capacity hits 36 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, with a magnetic trip threshold set at 4000 A. That 36 kA figure at 440 V is the rating that governs fault-clearing capability on a 400 V distribution bus — enough headroom for most industrial panelboards without stepping up to a higher frame.

Dimensions are 255 mm high, 140 mm wide, 110 mm deep — fits a standard panel footprint for a 400 A frame. Connection pitch is 44 mm. IP20 finger-safe protection on the front face; IK07 impact resistance means it handles incidental tool contact during panel wiring.

Frequently asked questions

Where can I buy EZC400N3300N and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does this brand provide for EZC400N3300N?

The breaker is certified to JIS C8201-2-2, EN/IEC 60947-2, and GB/T 14048.2. It also carries a suitability-for-isolation marking per IEC 60947-2.

MPN