Skip to main content
Schneider Electric EZCV250N3125 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZCV250N3125 EasyPact MCCB, 125A, 20kA, 3

MPNEZCV250N3125
Obsolete

Schneider Electric EasyPact EZCV250N series, EZCV250N3125, 3-pole MCCB, 125 A rated, 20 kA Icu at 440 V AC, TM-D thermal-magnetic trip unit with earth-leakage protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZCV250N3125 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250N3125 — Mechanical
ParameterValue
Height165 mm
Width105 mm
Depth68 mm
EZCV250N3125 — Electrical
ParameterValue
[In] rated current125 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250N3125 — Specifications
ParameterValue
Poles description3P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250N
StandardsEN/IEC 60947-2 EN/IEC 60947-1 JIS C8201-2-2 GB/T 14048.2

Product details

The Schneider Electric EZCV250N3125 is a 3-pole moulded-case circuit breaker from the EasyPact EZCV250N range, rated 125 A at 40 °C with a TM-D thermal-magnetic trip unit and integral earth-leakage protection. It's built for distribution duty in fixed-mount backplate panels, with front connections top and bottom and a 35 mm connection pitch. The 20 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2 tells you it can safely interrupt a fault up to that level without welding or rupturing — that's the short-circuit rating that governs selectivity in a distribution board. The N breaking capacity code places it in the standard-performance tier; for higher fault currents you'd step up to an S or H code in the same frame.

Above 40 °C you derate per the IEC curve; the TM-D unit responds to both overload (thermal bimetal) and short-circuit (magnetic trip). The 20 kA Icu at 440 V AC is the ultimate breaking capacity — the breaker clears that fault once and remains serviceable. At 380–415 V it rises to 25 kA Icu, and at 220–240 V it hits 85 kA Icu. The 440 V rated operational voltage (Ue) matches common 400 V class distribution systems. IK07 impact resistance handles light tool drops during installation.

Frequently asked questions

Where can I buy EZCV250N3125 and how do I get a price?

The EZCV250N3125 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of EZCV250N3125?

Rated 125 A at 40 °C, 3-pole, 20 kA Icu at 440 V AC, with a TM-D thermal-magnetic trip unit and integral earth-leakage protection.

What compliance documentation does this brand provide for EZCV250N3125?

The breaker complies with EN/IEC 60947-2, EN/IEC 60947-1, JIS C8201-2-2, and GB/T 14048.2 standards.

MPN
EZCV250N3125