Skip to main content
Schneider Electric EZCV250N44080 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZCV250N44080 EasyPact MCCB, 80 A, 20 kA

MPNEZCV250N44080
Obsolete

Schneider Electric EasyPact EZCV250N, 4-pole MCCB, 80 A thermal-magnetic TM-D trip, 20 kA Icu at 440 V AC, 50/60 Hz, IP20, IK07, backplate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZCV250N44080 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250N44080 — Mechanical
ParameterValue
Height165 mm
Width140 mm
Depth68 mm
EZCV250N44080 — Electrical
ParameterValue
[In] rated current80 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250N44080 — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250N
StandardsJIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

The Schneider Electric EZCV250N44080 is a 4-pole EasyPact EZCV250N moulded-case circuit breaker rated 80 A at 40 °C with a TM-D thermal-magnetic trip unit. It delivers 20 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2, with a Category A utilization class — meaning it's not intended for selective coordination downstream but is fine for branch-circuit protection in distribution panels.

Breaking capacity — what the N code means

The N breaking-capacity code on this EasyPact EZCV250N gives 20 kA Icu at 440 V AC, 25 kA at 380–415 V, and 85 kA at 220–240 V. For a 440 V distribution board, 20 kA Icu is enough for most secondary feeders; if your upstream transformer can push more fault current, you'd step up to the H or L code in the same frame size.

Connection pitch is 35 mm, so it fits standard busbar systems. The breaker measures 165 mm high × 140 mm wide × 68 mm deep — check your enclosure depth if you're retrofitting into a shallow panel. IP20 finger-safe terminals; IK07 impact resistance means it survives a 2 J hammer blow during installation.

Complies with JIS C8201-2-2, EN/IEC 60947-2, GB/T 14048.2, and EN/IEC 60947-1. Pollution degree 3 and suitability for isolation per IEC 60947-2 are the key approvals for an industrial panel builder.

Frequently asked questions

What is the closest alternative to the EZCV250N44080 in the same family?

Within the EasyPact EZCV250N range, the closest alternative would be a different breaking-capacity code (H or L) or a different trip rating — the frame and pole configuration are shared. No pin-compatible drop-in exists with a different brand; the TM-D trip and 4-pole layout are specific to this order code.

MPN
EZCV250N44080